5.2.2 Water supply
NOTICE!
The steam generator is suitable to be operated
with normal, softened or distilled water. It is per-
missible to add the lime binding agent Lapidon at
. VEIT will not accept liability
for function and safety of the device when adding
any other chemicals.
Only cold water must be used as the feedwater.
NOTICE!
Complete functionality is guaranteed with a con-
ductivity of 2.5 μS/cm and higher. Limited opera-
tion must be taken into account with a conductivity
of 1.5–2.5 μS/cm. Functionality cannot be guaran-
teed with a conductivity below 1.5 μS/cm.
CAUTION!
Make sure that no liquids enter the device. If
this is the case, switch off the steam generator
and unplug the connector of the mains connection
cable. The steam generator may only be started
again if it is in a completely dry state.
CAUTION!
When using contaminated water, the filter or the
3/2-way valve in the door may be clogged. As a
result the runtime of the pump becomes extremely
long or the functions fail completely
ð
Replace the
filter, clean the valve.
5.2.2.1
Water supply via water storage tank
The housing of the SG67 steam generator also is the water
storage tank which is filled manually.
To fill the tank, remove the cover (1) and fill in water.
Then place the cover (1) on the tank again
ð
Protection against
contamination of the feedwater.
CAUTION!
Make sure that no water is spilled on the upper
side of the steam generator.
Installation
Connections > Water supply
30.09.2022
Steam generator VEIT SG67
29