Standard ITU-T G.783 and ANSI T1.105.03 and Bellcore GR-253 sequences;
- Sequence:
Decide how to affect the pointer sequence.
-
Basic:
Specify whether the pointer is increasing or decreasing.
• Select Inc to increase the pointer value.
• Select Dec to decrease the pointer value.
• Select New Value to set new pointer value.
-
Single Alternating:
increase or decrease the pointer value.
-
Burst:
generate a sequence of changes in the pointer value in one direction only (increase or decrease).
-
Transient Burst:
generate changes in the phase of the pointer adjustment.
-
Periodic:
generate periodic changes in the pointer value.
-
87-3:
generate an 87-3 pattern (87 consecutive pointer adjustments, 3 consecutive pointer value, with no adjustments).
-
87-3 Add
: generate an 87-3 pattern (87 consecutive pointer adjustments, 3 consecutive pointer value, with added to have an
additional pointer value).
-
87-3 Cancel
: generate an 87-3 pattern (87 consecutive pointer adjustments, 3 consecutive pointer value, with reduce the
number of adjustments by one).
-
Unit
: Select the type of unit to count :Frames
N: Specify the number of pointer adjustments in a row: 1—9999 (default=6)
T: Specify the average pointer spacing in time. T is known as T1 to T5 in G.783: (default=4)
T1, T4: 0.25ms to 600 s or 2 to 4,800,000 frames/multiframes
T2, T3: 0.25ms to 10 s or 2 to 80,000 frames/multiframes
T5: 0ms to 600s or 0 to 4,800,000 frames/multiframes
TX150 e-Manual D07-00-023 Rev A02
Page 85 of 107