Monitor:
To be used when the measurement is made at a Protected Monitoring Point (PMP) of network equipment. The PMP
level can range between -20 and -26dB.
-
Bridge:
Available on in DS1 or E1 mode. Select this mode for a high impedance monitor test or when the receiver is
connected directly in parallel to an DS1 or E1 line carrying live traffic. The isolation circuit of the unit protects the DS1 or E1
signal from any possible disruption.
LINE CODE:
The line code for testing at the various Rx bit rates is the same for the Tx described previously. The termination
settings in this Rx setup, however, have no effect on the Tx.
7.3.3 Rx Setup > Payload
Tapping the Payload box opens the Rx Payload Setup screen.
RATE:
Same options as Transmitter described previously.
FRAMING:
Same options as Transmitter described previously
When the Nx64 fractional rate is selected, the following screen is displayed;
TX150 e-Manual D07-00-023 Rev A02