SDH Mode
SONET Mode
SDH/SONET
: To setup the SONET or SDH mode, first tab on the setup icon. In the Setup screen, tab the Measurements and
tab the General. This application allows the user to set up the SONET or SDH interfaces and associated test parameters prior to
running a test.
Result on start:
The automatic move to results screen, tap the Results on start set to "ON" and it will move automatically to
the Results screen.
Auto Save:
To automatic save results file, tab the Auto save set to "ON" will automatically saved the results file.
7.1 Signal Overview
The Transmitter and Receiver configurations are grouped into a simple yet intuitive block diagram. The Tx and Rx signal
parameters can be modified by tapping the applicable block which brings up a new dialog window displaying additional input and
specific selection settings. The transmitter transmits as soon as a valid configuration is entered. The receiver will check for a valid
signal on its input so the measurement function is synchronized. When a test is not running, the LEDs will still indicate errors and
alarms but any other results displayed will be the results of a previous test.
When the Tx and Rx signal structures are required to be identical or symmetrical, coupling the Transmitter and Receiver is
possible. The signal structure can be copied from Tx to the Rx, or vice versa.
TX150 e-Manual D07-00-023 Rev A02
Page 11 of 107