The following
PDH and T-Carrier errors
can be generated;
PDH/DSn error types:
- DS1 signals: Code, FAS, Bit
- DS3 signals: Code, FAS, Bit
- E1 signals: Code, FAS, CRC, REI, E-bit, Bit
- E3 signals: Code, FAS, Bit
The following
SONET errors
can be generated;
SONET error types:
- OC-3/12/48 signals: FAS, B1, B2, REI-S, B3, RE-PI, BIP-V, REI-V,
- Depends on payload: 2M-FAS, 2M-CRC, 2M-REI, 34M-FAS, 45M-FAS, 1.5M-FAS
Error Flow
Inject a range of different anomalies into the transmit signal. Error insertion modes include;
- Single: Inserts a single error every time the insertion button is tapped
- Count: Specific count or number of errors when the insertion button is tapped
- Rate: Specific rate between 1^10
-3
and 5^10
-6
The list of available error types depends on the type of framing being used, and the SONET or PDH/DSn hierarchies and line
interfaces that have been selected.
TX150 e-Manual D07-00-023 Rev A02