Air regulator installation and operation
1. Firmly tight and seal the copper air hole at IN and OUT terminal by high
pressure rubber tube .
2.Tight and seal the meter with meter face rubber tube.
3.Fix the connecting shelf with screw as the regulator position.
4.Get down the plastic screw and fix the regulator on the shelf.
5.Turn on the air valve, turn up the pressure adjusting knob, turn the pressure
volume (meter inside shows kg), and then put down the knob.(+ means increasing
pressure, -- means decreasing pressure.)
6.Scale of the meter is as follow. The volume in the picture is 6 kg.
7. If the water in thegas filtering bottle is too much, please turn on the water valve to
let the water go out.
Connecting shelf
Pressure adjusting knob
Compressed air
Pressure meter
Air filting bottle
Air pipe
Air out
Air in
Drainage interface
CUTTING
SERIES
EQUIPMENT
Operation
CAUTION
CAUTION
CAUTION
Do not point the torch jet at foreign bodies.
Avoid unnecessary lighting of the pilot arc toprevent excessive
consumption of the electrodeand nozzle.
Cutting torch
power supply
During cutting the speed of the torch movement should be in accordance with the
thickness of the piece to be cut. Excessive speed causes a return of incandescent
towards the torch which shortens the life of the parts of the torch most subject to
Air compressor
wear and tear. The metal fouling on the nozzle should be removed as soon as possible.