Number
Description
Range
Value
Default
1400
Setpoint and Temperature Settings
1401
1402
1403
1404
1405
1406
1407
Setpoint adjustment is valid till
0 = only present day (0..24 hrs)
1 = total program is moved
2 = till the next setpoint change
Setpoint step changed by slope
Maximum slope per hour of setpoint
(if 1402 = 1)
Read-out in °F
Dampening factor of display
Maximum setpoint during programming
Minimum setpoint during programming
0..2
0..1
0.1..20.0
0..1
1..5
-10..40.0
-10..40.0
-
-
°C
-
-
-
-
0
0
0.5
0
3
25.0
10.0
1500
Time Setting
1501
Length of a day
6..96
hrs.
24
1600
Gassing and Ventilation Settings
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
Maximum gas time during control on
gas concentration
Venting at maximum gas level
Venting during gassing if maximum
gas level is exceeded
Maximum gas level
Differential maximum gas level
Venting at maximum CO2 level
Venting during gassing if maximum
CO2 level is exceeded
Maximum CO2 level
Differential maximum CO2 level
Number of gas carrousel
1..3000
0..1
0..1
0..2000
1..1000
0..1
0..1
0..3000
1..1000
0..99
min
-
-
ppm
ppm
-
-
ppm
ppm
-
40
0
0
2000
500
0
0
3000
100
0
Содержание PROBA
Страница 73: ...VDH Products BV Document 063319 version 3 12 Page 73 of 78...
Страница 74: ...VDH Products BV Document 063319 version 3 12 Page 74 of 78 Appendix M Technical Specification PROBA110...
Страница 75: ...VDH Products BV Document 063319 version 3 12 Page 75 of 78...
Страница 76: ...VDH Products BV Document 063319 version 3 12 Page 76 of 78...
Страница 77: ...VDH Products BV Document 063319 version 3 12 Page 77 of 78 Jumper settings...