VDH Products BV
Document 063319 - version 3.12
Page:
30 of 78
Rotate the key switch to the
ON
position and remove the key from the switch.
Please note:
Unless stated otherwise when setting parameter, 0 = NO and 1 = YES.
4.2.1
General settings of the PROBA110
General Settings are under the following main groups:
Parameter
Description
0000
General
7000
Function test
8000
Password
Explanation:
0001
This parameter offers the opportunity to set all parameters back to a standard value. The value of this
parameter can only be changed if no program is running. Acknowledge the new value by pressing the
SENS/TIME
,
PROG
and
ZONE/HEAT
keys at the same time.
0002
The network number is used in network systems. This should be a unique number for the
PROBA110
.
This is usually the ripening room number.
0003
If the
PROBA110
is used as thermostat for holding or transit rooms, this parameter can be used for fix
the
PROBA110
into the STANDBY mode. It is not possible to start a ripening program.
7001
The parameters 7001 to 7020 are used to force relays to switch on. With this function the operation of
equipment, connected to the relays, can be tested. When the Parameter settings are left, the relays
switch back to their normal position.
7031
The parameters 7031 to 7040 give the present status of the digital input. A '0' means the input is open, a
'1' means the input is closed.
7051
The parameters 7051 to 7058 show the present output level of the analog outputs in percent. The actual
output signal depends on the chosen range (0/+10Vdc or 4/+20mA).
7061
Parameters 7061 to 7067 display the level of the input signal of the analog inputs in percent. Depending
on the chosen input, the real input signal can be calculated.
7070
With the display test all displays on the
PROBA110
can be switched on.
7080
The fans will reverse after 10 seconds
8001
Here a password can be entered. If this password is similar to the password of parameter 8002 one gains
access to the 8000 group.
8010
This parameter blocks changing of parameters 0001 to 0006. This is to prevent accidental changes to
important parameters. The same applies to parameters 8011 to 8029.
4.2.2
Program settings of the PROBA110
Programma Settings are under the following main groups:
Parameter
Description
0100
Default programs
0200
Day 0 for programs 1 to 10
0300
Programming programs 1 to 10
0400
Day 0 for programs 11 to 20
0500
Programming programs 11 to 20
Содержание PROBA
Страница 73: ...VDH Products BV Document 063319 version 3 12 Page 73 of 78...
Страница 74: ...VDH Products BV Document 063319 version 3 12 Page 74 of 78 Appendix M Technical Specification PROBA110...
Страница 75: ...VDH Products BV Document 063319 version 3 12 Page 75 of 78...
Страница 76: ...VDH Products BV Document 063319 version 3 12 Page 76 of 78...
Страница 77: ...VDH Products BV Document 063319 version 3 12 Page 77 of 78 Jumper settings...