Shrink Tunnel VC999 ST2/ST2 D
Operating messages and faults
2009-11-12
Art. no. 593.767
Page 67/96
No.
Error message
Possible cause
Remedy
F12 Main
contactor
heaters
The safety functions of
the heaters malfunction-
ing (floating switch "Low
water" or heater contac-
tors)
Press the EMERGENCY STOP button and
then the RESET button in order to unlock the
EMERGENCY STOP. Check whether the float-
ing switch "Low water" has switched correctly.
If the error re-occurs, contact the VC999 Cus-
tomer Service Department.
F20 Water level
One of the floating
switches malfunctioning
The floating switch may have to be replaced.
Contact the VC999 Customer Service Depart-
ment
The water temperature
outside the set normal
range (+/- 5 °C).
F21 Temperature
mo-
nitoring
An incorrect water tem-
perature imported
Check the following for defects:
Electric heater
Heater contactors
PT100 sensor
Analog/Digital module (check analog value at
the display)
Conveyor belt too tight
Check the transport area
F31 Transport
drives
The gear motor defec-
tive
Read error code and contact the VC999 Cus-
tomer Service Department
F39 Photoel. sensor
The photocell actuated
for longer than 10 mins.
Check the photocell setting.
F40 Warning
decalcifier
Decalcifier almost emp-
ty.
Check the floating switch in the standard de-
calcifier canister
If necessary, refill decalcifier or replace the
empty standard decalcifier canister with a full
one.
F41 Decalcifier
ex-
hausted!
Decalcifier empty
Check the floating switch in the standard de-
calcifier canister
If necessary, refill decalcifier or replace the
empty standard decalcifier canister with a full
one.
F50 Heating line pro-
tection
Line protection or a hea-
ter has tripped.
Check which line protection has tripped.
Check the corresponding heater for short-
circuiting.
Reset the protective switch.
F51 Steam
extractor
or water pump
The protective motor
switch of the steam ex-
tractor fan or the water
pump has tripped.
Check the steam extractor fan and the water
pump and reset the protective motor switch.
Содержание 593.767
Страница 4: ......
Страница 41: ...Shrink Tunnel VC999 ST2 ST2 D Operation 2009 11 12 Art no 593 767 Page 41 96 Fig 9 3...
Страница 81: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams 2009 11 12 Art no 593 767 Page 81 96 16 Circuit diagrams...
Страница 82: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams Page 82 96 Art no 593 767 2009 11 12...
Страница 83: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams 2009 11 12 Art no 593 767 Page 83 96...
Страница 84: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams Page 84 96 Art no 593 767 2009 11 12...
Страница 85: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams 2009 11 12 Art no 593 767 Page 85 96...
Страница 86: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams Page 86 96 Art no 593 767 2009 11 12...
Страница 87: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams 2009 11 12 Art no 593 767 Page 87 96...
Страница 88: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams Page 88 96 Art no 593 767 2009 11 12...
Страница 89: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams 2009 11 12 Art no 593 767 Page 89 96...
Страница 90: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams Page 90 96 Art no 593 767 2009 11 12...
Страница 91: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams 2009 11 12 Art no 593 767 Page 91 96...
Страница 92: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams Page 92 96 Art no 593 767 2009 11 12...
Страница 93: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams 2009 11 12 Art no 593 767 Page 93 96...
Страница 94: ...Shrink Tunnel VC999 ST2 ST2 D Circuit diagrams Page 94 96 Art no 593 767 2009 11 12...