VDF650
User
Manual
Desc
ription
of
Function
Codes
-
165
-
If
the
frequency
source
is multi-reference, the
value
100
%
of
FC
-
00
to
FC
-
15
corresponds to
the
value
of
P0
-
10
(
Maximum
frequency
).
Besides
the
multi
-
speed
function
,
the
multi
-
reference can be
also used
as the PID setting
source
or
the
voltage
source
for
V
/
F
separation
,
satisfying
the
requirement
on
switchover
of
different
setting
values
.
Two
terminals
for
acceleration
/
deceleration
time
selection
have
four
state
combinations
,
as
listed
in
the
following
table
.
Table
6
-
3
State
combinations
of
two
terminals
for
acceleration
/
deceleration
time
selection
Terminal
2
Terminal
1
Acceleration
/
Deceleration
Time
Selection
Corresponding
Parameters
OFF
OFF
Acceleration
/
Deceleration
time
1
P0
-
17
,
P0
-
18
OFF
ON
Acceleration
/
Deceleration
time
2
P8
-
03
,
P8
-
04
ON
OFF
Acceleration
/
Deceleration
time
3
P8
-
05
,
P8
-
06
ON
ON
Acceleration
/
Deceleration
time
4
P8
-
07
,
P8
-
08
Two
motor
selection
terminals
have
four
state
combinations
,
corresponding
to
four
motors
,
as
listed
in
the
following
table
.
Table
6
-
4
State
combinations
of
two
motor
selection
terminals
Terminal
2
Terminal
1
Selected
Motor
Corresponding
Parameters
OFF
OFF
Motor
1
Group
P1
,
Group
P2
OFF
ON
Motor
2
Group
A2
ON
OFF
Motor
3
Group
A3
ON
ON
Motor
4
Group
A4
Function
Code
Parameter
Name
Setting
Range
Default
P4
-
10
DI
flter
time
0
.
000
–
1
.
000s
0
.
010s
It is used to set the software filter time of DI terminal status
.
If DI terminals are liable to
interference and
may
cause
malfunction
,
increase
the
value
of
this parameter to enhance
the
anti
-
interference
capability
.
However
,
increase
of
DI
flter
time
will
reduce
the
response
of
DI
terminals
.
Function
Code
Parameter
Name
Setting
Range
Default
P4
-
11
Terminal
command
mode
0
:
Two
-
line
mode
1
1
:
Two
-
line
mode
2
2
:
Three
-
line
mode
1
3
:
Three
-
line
mode
2
0
This parameter is used to set the mode in which the AC drive is controlled by external
terminals
.
The following uses DI1
,
DI2 and DI3 among DI1 to DI10 as an example
,
with
allocating
functions
of
DI1
,
DI2
and
DI3
by
setting
P4
-
00
to
P4
-
02
.
Содержание VDF650 Series
Страница 1: ...VDF650 Series High Performance AC Drive...
Страница 9: ......
Страница 10: ...1 Safety Information and Precautions...
Страница 17: ...Safety Information and Precautions VDF650 User Manual 16...
Страница 18: ...2 Product Information...
Страница 29: ...Product Information VDF650 User Manual 28...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 46: ...4 Operation Display and Application Examples...
Страница 79: ...Operation Display and Application Examples VDF650 User Manual 78...
Страница 80: ...5 Function Code Table...
Страница 136: ...6 Description of Function Codes...
Страница 248: ...7 EMC...
Страница 260: ...8 Selection and Dimensions...
Страница 285: ...Selection and Dimensions VDF650 User Manual 284...
Страница 286: ...9 Maintenance and Troubleshooting...