VDF650
User
Manual
Desc
ription
of
Function
Codes
-
155
-
Function
Code
Parameter
Name
Setting
Range
Default
P2
-
13
Excitation
adjustment
proportional
gain
0
–
20000
2000
P2
-
14
Excitation
adjustment
integral
gain
0
–
20000
1300
P2
-
15
Torque
adjustment
proportional
gain
0
–
20000
2000
P2
-
16
Torque
adjustment
integral
gain
0
–
20000
1300
These are current
loop
PI parameters
for
vector
control
.
These
parameters
are
automatically
obtained
through
"
Asynchronous
motor
complete
auto
-
tuning
"
or
"
Synchronous motor no
-
load
auto
-
tuning
",
and
need
not
be
modifed
.
The
dimension
of
the
current
loop
integral
regulator
is
integral
gain
rather
than
integral
time
.
Note that too
large current loop PI
gain
may lead to
oscillation of
the entire control loop
.
Therefore
,
when current oscillation or torque fluctuation is great
,
manually decrease the
proportional
gain
or
integral
gain
here
.
Function
Code
Parameter
Name
Setting
Range
Default
P2
-
18
Field
weakening
mode
of
synchronous
motor
0
:
No
feld
weakening
1
:
Direct
calculation
2
:
Automatic
adjustment
1
P2
-
19
Field
weakening
depth
of
synchronous
motor
50
%–
500
%
100
%
P2
-
20
Maximum
feld
weakening
current
1
%–
300
%
50
%
P2
-
21
Field
weakening
automatic
adjustment
gain
10
%–
500
%
100
%
P2
-
22
Field
weakening
integral
multiple
2
–
10
2
These
parameters
are
used
to
set
feld
weakening
control
for
the
synchronous
motor
.
If
P2
-
18
is
set to
0
,
feld
weakening
control on
the synchronous motor is disabled
.
In
this
case
,
the maximum rotational speed is
related
to
the
AC drive bus voltage
.
If
the
motor
'
s
maximum rotational speed cannot meet the requirements
,
enable the field weakening
function
to
increase
the
speed
.
The VDF650 provides two field weakening modes
:
direct calculation and automatic
adjustment
.
•
In
direct calculation mode
,
directly
calculate the
demagnetized current
and
manually
adjust the demagnetized current by means of
P2
-
19
.
The smaller the demagnetized
current
is
,
the
smaller
the
total
output
current
is
.
However
,
the
desired
feld
weakening
effect
may
not
be
achieved
.
•
In automatic
adjustment
mode
,
the best
demagnetized
current
is
selected
automatically
.
This
may
infuence
the
system
dynamic
performance
or
cause
instability
.
The adjustment speed of the field weakening current can be changed by modifying the
values of P2
-
21 and P2
-
22
.
A very quick adjustment may cause instability
.
Therefore
,
generally
do
not
modify
them
manually
.
Содержание VDF650 Series
Страница 1: ...VDF650 Series High Performance AC Drive...
Страница 9: ......
Страница 10: ...1 Safety Information and Precautions...
Страница 17: ...Safety Information and Precautions VDF650 User Manual 16...
Страница 18: ...2 Product Information...
Страница 29: ...Product Information VDF650 User Manual 28...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 46: ...4 Operation Display and Application Examples...
Страница 79: ...Operation Display and Application Examples VDF650 User Manual 78...
Страница 80: ...5 Function Code Table...
Страница 136: ...6 Description of Function Codes...
Страница 248: ...7 EMC...
Страница 260: ...8 Selection and Dimensions...
Страница 285: ...Selection and Dimensions VDF650 User Manual 284...
Страница 286: ...9 Maintenance and Troubleshooting...