Description
of
Function
Codes
VDF650
User
Manual
-
240
-
Function
Code
Parameter
Name
Setting
Range
Default
AC
-
12
AO1
target
voltage
1
0
.
500
–
4
.
000
V
Factory
-
corrected
AC
-
13
AO1
measured
voltage
1
0
.
500
–
4
.
000
V
Factory
-
corrected
AC
-
14
AO1
target
voltage
2
6
.
000
–.
999
V
Factory
-
corrected
AC
-
15
AO1
measured
voltage
2
6
.
000
–
9
.
999
V
Factory
-
corrected
AC
-
16
AO2
target
voltage
1
0
.
500
–
4
.
000
V
Factory
-
corrected
AC
-
17
AO2
measured
voltage
1
0
.
500
–
4
.
000
V
Factory
-
corrected
AC
-
18
AO2
target
voltage
2
6
.
000
–
9
.
999
V
Factory
-
corrected
AC
-
19
AO2
measured
voltage
2
6
.
000
–
9
.
999
V
Factory
-
corrected
AC
-
20
AI2
measured
current
1
0
.
000
–
20
.
000
mA
Factory
corrected
AC
-
21
AI2
sampling
current
1
0
.
000
–
20
.
000
mA
Factory
corrected
AC
-
22
AI2
measured
current
2
0
.
000
–
20
.
000
mA
Factory
corrected
AC
-
23
AI2
sampling
current
2
0
.
000
–
20
.
000
mA
Factory
corrected
AC
-
24
AO1
ideal
current
1
0
.
000
–
20
.
000
mA
Factory
corrected
AC
-
25
AO1
sampling
current
1
0
.
000
–
20
.
000
mA
Factory
corrected
AC
-
26
AO1
ideal
current
2
0
.
000
–
20
.
000
mA
Factory
corrected
AC
-
27
AO1
sampling
current
2
0
.
000
–
20
.
000
mA
Factory
corrected
These
parameters
are
used
to
correct
the
AO
.
They have been corrected upon delivery
.
When you resume the factory values
,
these
parameters
will
be
restored
to
the
factory
-
corrected
values
.
You
need
not
perform
correction
in
the
applications
.
Target voltage indicates the
theoretical output voltage of the AC drive
.
Measured voltage
indicates
the
actual
output
voltage
value
measured
by
instruments
such
as
the
multimeter
.
Group
U0
:
Monitoring
Parameters
Group U0 is used to monitor the AC drive
'
s running state
.
You can view the parameter
values by using operation panel
,
convenient for on
-
site commissioning
,
or from the host
computer
by
means
of
communication
(
address
:
0x7000
-
0x7044
).
U0
-
00
to
U0
-
31
are
the
monitoring
parameters
in
the
running
and
stop
state
defned
by
P7
-
03
and
P7
-
04
.
For
more
details
,
see
Table
6
-
1
.
Function
Code
Parameter
Name
Display
Range
U0
-
00
Running
frequency
0
.
00
–
320
.
00
Hz
(
P0
-
22
=
2
)
U0
-
01
Set
frequency
0
.
00
–
3200
.
0
Hz
(
P0
-
22
=
1
)
These two
parameters
display
the
absolute
value
of
theoretical
running
frequency
and set
frequency
.
For
the
actual
output
frequency
of
the
AC
drive
,
see
U0
-
19
.
Function
Code
Parameter
Name
Display
Range
U0
-
02
Bus
voltage
0
.
0
–
3000
.
0
V
It
displays
the
AC
drive
'
s
bus
voltage
.
Содержание VDF650 Series
Страница 1: ...VDF650 Series High Performance AC Drive...
Страница 9: ......
Страница 10: ...1 Safety Information and Precautions...
Страница 17: ...Safety Information and Precautions VDF650 User Manual 16...
Страница 18: ...2 Product Information...
Страница 29: ...Product Information VDF650 User Manual 28...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 46: ...4 Operation Display and Application Examples...
Страница 79: ...Operation Display and Application Examples VDF650 User Manual 78...
Страница 80: ...5 Function Code Table...
Страница 136: ...6 Description of Function Codes...
Страница 248: ...7 EMC...
Страница 260: ...8 Selection and Dimensions...
Страница 285: ...Selection and Dimensions VDF650 User Manual 284...
Страница 286: ...9 Maintenance and Troubleshooting...