Operation
,
Display
and
Application
Examples
VDF650
User
Manual
-
66
-
4
.
8
.
9
Setting
the
Motor
Rotating
Direction
After
the
AC
drive
restores
the
default
settings
,
press
RUN
to
drive
the
motor
to
rotate
.
In
this
case
,
the
rotating
direction
is
regarded
as
the
forward
rotation
.
If
the
rotating
direction
is
reverse
to
the
direction
required
by
the equipment
,
power
off the AC
drive
and
exchange any
two
of
the
output
UVW cables
(
wait
until the
main capacitor of the
AC
drive
is
completely
discharged
).
In
some
applications
where
both
forward
rotation
and
reverse
rotation
are
required
,
enable
the
reverse
control
(
P8
-
13
=
0
,
default
value
)
and
meanwhile
reverse
the
rotating
direction
by
setting
P0
-
09
to
1
.
Then
press
RUN
to
make
the
motor
rotate
in
the
reverse
direction
,
as
shown
in
the
following
fgure
.
Figure
4
-
26
Reversing
the
motor
rotating
direction
Command
source
(
operation
panel control
)
Forward
rotation
command
(
terminal
,
communication
)
Reverse
rotation
command
Fs
>
0
Fs
≤
0
Fs
≤
0
Fs
>
0
P0
-
09
0
0
1
1
0
1
P8
-
13
(
terminal
,
communication
)
Set
frequency
Rotating
direction
setting
Reverse
control
enabled
Forward
rotation
Reverse
rotation
Rotating
at 0
.
0
Hz
If
the
command
source
is
terminal
control
and
reverse
rotation
is
required
,
use
the
default
value
0
of
P8
-
13
to
enable
reverse
control
.
According to the preceding figure
,
when the running frequency of the AC drive is set by
means of communication
(
P0
-
03
=
9
)
and reverse control is enabled
(
P8
-
13
=
0
),
the AC
drive
instructs
the
reverse
direction
if
the
set
frequency
Fs
is
a
negative
value
.
If
the
give
running
command
is
reverse
rotation
or
the
set
frequency
is
a
negative
value
,
but
reverse
control
is
disabled
(
P8
-
13
=
1
),
the
AC
drive
will
run
at
0
Hz
and
has
no
output
.
In some applications where reverse rotation is prohibited
,
do not change the rotating
direction
by
modifying
the
function
codes
because
the
function
codes
will
be
restored
once
the
AC
drive
restores
the
default
settings
.
4
.
8
.
10
Setting
the
Fixed
Length
Control
Mode
The
VDF650
has
the
fxed
length
control
function
.
The
length
pulses
are
sampled
by
the
DI
allocated
with
function
27
(
Length
count
input
).
The
"
Actual
length
" (
PB
-
06
)
is
obtained
by
dividing
the
number
of
pulses
sampled
by
the
value
of
PB
-
07
(
Number
of
pulses
per
meter
).
If
the
actual
length
is
larger than the
"
Set length
" (
PB
-
05
),
the
multifunctional
DO
terminal
becomes
ON
.
In
the
process
of
fxed
length
control
,
the
length
can
be
reset
by
means
of
the
DI
terminal
allocated
with
function
28
(
Length
reset
).
The
related
setting
is
shown
in
the
following
fgure
.
Содержание VDF650 Series
Страница 1: ...VDF650 Series High Performance AC Drive...
Страница 9: ......
Страница 10: ...1 Safety Information and Precautions...
Страница 17: ...Safety Information and Precautions VDF650 User Manual 16...
Страница 18: ...2 Product Information...
Страница 29: ...Product Information VDF650 User Manual 28...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 46: ...4 Operation Display and Application Examples...
Страница 79: ...Operation Display and Application Examples VDF650 User Manual 78...
Страница 80: ...5 Function Code Table...
Страница 136: ...6 Description of Function Codes...
Страница 248: ...7 EMC...
Страница 260: ...8 Selection and Dimensions...
Страница 285: ...Selection and Dimensions VDF650 User Manual 284...
Страница 286: ...9 Maintenance and Troubleshooting...