VDF650
User
Manual
Desc
ription
of
Function
Codes
-
213
-
The swing
amplitude
is
set
in
PB
-
00
and
PB
-
01
.
When
PB
-
01
is
set
to
0
,
the
swing
amplitude
is
0
and
the
swing
frequency
does
not
take
effect
.
Figure
6
-
30
Swing
frequency
control
Time
(
t
)
Output
frequency
(
Hz
)
Set frequency Fset
Swing frequency
lower
limit
RUN
command
Swing
cycle
Triangular
rising
time
Decelerate by
deceleration time
Swing amplitude
Aw
=
Fset x PB
-
01
+
Aw
-
Aw
Textile
kick frequency
=
Aw xPB
-
02
Accelerate by
acceleration
time
Swing frequency
upper limit
Function
Code
Parameter
Name
Setting
Range
Default
PB
-
00
Swing
frequency
setting
mode
0
:
Relative
to
the
central
frequency
1
:
Relative
to
the
maximum
frequency
0
This
parameter
is
used
to
select
the
base
value
of
the
swing
amplitude
.
•
0
:
Relative
to
the
central
frequency
(
P0
-
07
frequency
source
selection
)
It is variable swing amplitude system
.
The swing amplitude varies with the central
frequency
(
set
frequency
).
•
1
:
Relative
to
the
maximum
frequency
(
P0
-
10
maximum
output
frequency
)
It
is
fxed
swing
amplitude
system
.
The
swing
amplitude
is
fxed
.
Function
Code
Parameter
Name
Setting
Range
Default
PB
-
01
Swing
frequency
amplitude
0
.
0
%–
100
.
0
%
0
.
0
%
PB
-
02
Jump
frequency
amplitude
0
.
0
%–
50
.
0
%
0
.
0
%
This parameter is used to determine the swing amplitude
and jump frequency amplitude
.
The
swing
frequency
is
limited
by
the
frequency
upper
limit
and
frequency
lower
limit
.
•
If
relative
to
the
central frequency
(
PB
-
00
=
0
),
the actual
swing
amplitude AW
is
the
calculation
result
of
P0
-
07
(
Frequency
source
selection
)
multiplied
by
PB
-
01
.
•
If
relative
to
the
maximum
frequency
(
PB
-
00
=
1
),
the
actual
swing
amplitude
AW
is
the
calculation
result
of
P0
-
10
(
Maximum
frequency
)
multiplied
by
PB
-
01
.
Jump
frequency
=
Swing
amplitude
AW
x
PB
-
02
(
Jump
frequency
amplitude
).
•
If
relative
to
the
central
frequency
(
PB
-
00
=
0
),
the
jump
frequency
is
a
variable
value
.
•
If
relative
to
the
maximum
frequency
(
PB
-
00
=
1
),
the
jump
frequency
is
a
fxed
value
.
The
swing
frequency
is
limited
by
the
frequency
upper
limit
and
frequency
lower
limit
.
Содержание VDF650 Series
Страница 1: ...VDF650 Series High Performance AC Drive...
Страница 9: ......
Страница 10: ...1 Safety Information and Precautions...
Страница 17: ...Safety Information and Precautions VDF650 User Manual 16...
Страница 18: ...2 Product Information...
Страница 29: ...Product Information VDF650 User Manual 28...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 46: ...4 Operation Display and Application Examples...
Страница 79: ...Operation Display and Application Examples VDF650 User Manual 78...
Страница 80: ...5 Function Code Table...
Страница 136: ...6 Description of Function Codes...
Страница 248: ...7 EMC...
Страница 260: ...8 Selection and Dimensions...
Страница 285: ...Selection and Dimensions VDF650 User Manual 284...
Страница 286: ...9 Maintenance and Troubleshooting...