Description
of
Function
Codes
VDF650
User
Manual
-
222
-
The VDF650 provides display of two types of individualized parameters
:
user
-
defined
parameters
and
user
-
modifed
parameters
.
•
You
-
defined parameters are included in group PE
.
You can add a maximum of 32
parameters
,
convenient
for
commissioning
.
In user
-
defined parameter mode
,
symbol
"
u
"
is added before the function code
.
For
example
,
P1
-
00
is
displayed
as
uP1
-
00
.
•
You
-
modifed
parameters
are
grouped
together
,
convenient
for
on
-
site
troubleshooting
.
In you
-
modifed parameter
mode
,
symbol
"
c
"
is added before
the function code
.
For
example
,
P1
-
00
is
displayed
as
cP1
-
00
.
Function
Code
Name
Setting
Range
Default
PP
-
04
Parameter
modifcation
property
0
:
Modifable
1
:
Not
modifable
0
It
is
used
to
set
whether
the
parameters
are
modifable
to
avoid
mal
-
function
.
If
it
is
set
to
0
,
all
parameters
are
modifable
.
If
it
is
set
to
1
,
all
parameters
can
only
be
viewed
.
Group
A0
:
Torque
Control
and
Restricting
Parameters
Function
Code
Parameter
Name
Setting
Range
Default
A0
-
00
Speed
/
Torque
control
selection
0
:
Speed
control
1
:
Torque
control
0
It
is
used
to
select
the
AC
drive
'
s
control
mode
:
speed
control
or
torque
control
.
The VDF650 provides DI terminals with two torque related functions
,
function 29
(
Torque
control
prohibited
)
and function
46
(
Speed control
/
Torque control switchover
).
The two DI
terminals need to be used together with
A0
-
00 to implement speed control
/
torque
control
switchover
.
If the DI terminal allocated with function 46
(
Speed control
/
Torque control switchover
)
is
OFF
,
the
control
mode
is
determined
by
A0
-
00
.
If
the
DI
terminal
allocated
with
function
46
is
ON
,
the
control
mode
is
reverse
to
the
value
of
A0
-
00
.
However
,
if
the
DI
terminal
with
function
29
(
Torque
control
prohibited
)
is
ON
,
the
AC
drive
is
fxed
to
run
in
the
speed
control
mode
.
Function
Code
Parameter
Name
Setting
Range
Default
A0
-
01
Torque
setting
source
in
torque
control
0
:
Digital
setting
(
A0
-
03
)
1
:
AI1
2
:
AI2
3
:
AI3
4
:
Pulse
setting
(
DI5
)
5
:
Communication
setting
6
:
MIN
(
AI1
,
AI2
)
7
:
MAX
(
AI1
,
AI2
)
0
A0
-
03
Torque
digital
setting
in
torque
control
-
200
.
0
%–+
200
.
0
%
150
.
0
%
Содержание VDF650 Series
Страница 1: ...VDF650 Series High Performance AC Drive...
Страница 9: ......
Страница 10: ...1 Safety Information and Precautions...
Страница 17: ...Safety Information and Precautions VDF650 User Manual 16...
Страница 18: ...2 Product Information...
Страница 29: ...Product Information VDF650 User Manual 28...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 46: ...4 Operation Display and Application Examples...
Страница 79: ...Operation Display and Application Examples VDF650 User Manual 78...
Страница 80: ...5 Function Code Table...
Страница 136: ...6 Description of Function Codes...
Страница 248: ...7 EMC...
Страница 260: ...8 Selection and Dimensions...
Страница 285: ...Selection and Dimensions VDF650 User Manual 284...
Страница 286: ...9 Maintenance and Troubleshooting...