RECEIPT OF DELIVERY
vacon • 13
24-hour s358 (0)40 837 1150 • Email: [email protected]
3
3.
RECEIPT OF DELIVERY
The standard delivery of Vacon liquid-cooled drives includes all or part of the following components:
o
power unit
o
control unit
o
main line connecting hoses and conduits
(1.5m) + aluminium adapters for Ch5-
Ch74; Hoses in different lengths also
available
o
Tema 1300 series fast connectors for
Ch3-Ch4
o
choke (not DC-fed inverters, type code I)
o
control unit mounting kit
o
cooling fan for boards (CH4)
o
optic fibre & cable set (1.5m) for control
unit; Optic sets in different lengths also
available
o
optic fibre cable set for 2*CH64/CH74:
1.8m/11 fibres (Power module 1) and
3.8m/8 fibres (Power module 2)
Vacon liquid-cooled frequency converters have undergone scrupulous tests and quality checks at the fac-
tory before they are delivered to the customer. However, after unpacking the product, check that no signs
of transport damages are to be found on the product and that the delivery is complete (compare the type
designation of the product to the code below, Figure 3-1).
Should the drive have been damaged during the shipping, please contact primarily the cargo insurance
company or the carrier.
If the delivery does not correspond to your order, contact the supplier immediately.
3.1
Type designation code
The type designation code for the NX Liquid-Cooled drives is presented below. Should you need more or
closer information about the type code, see Appendix 1.
NXP
0000
A 0 N 1 SWV* A1A20000C3
5
nkw3_1.fh8
Product range: NXP = high-performance, NXB = brake chopper unit,
NXA = AFE unit, NXI = inverter unit
Nominal current (low overload)
0007 = 7 A, 0022 = 22 A, 0205 = 205 A etc.
Nominal mains voltage (3-phase):
5 = 380–500Vac, 6 = 525–690Vac (All 3-phase)
Control keypad:
A = standard (alpha-numeric)
B = neutral (no local control keypad)
F = dummy panel
Enclosure class:
0 = IP00
EMC emission level:
N = No EMC emission protection; to be installed in enclosures
T = Fulfils standard 61800-3 for IT networks
Brake chopper
0 = no brake chopper
1 = internal brake chopper (CH3 only)
Hardware modifications; Supply - Mounting - Boards
F = Fiber connection/standard (from CH61)
G = Fiber connection/varnished (from CH61)
S = Direct connection/standard
V = Direct connection/varnished
Option boards; each slot is represented by two characters where:
A = basic I/O board, B = expander I/O board,
C = fieldbus board, D = special board
*See more information in Appendix 1
W = Liquid-cooled module
I = Inverter unit; DC-supply
S = Standard supply; 6-pulse connection with chokes
N = Standard supply; 6-pulse connection without chokes
T = 12-pulse connection (with chokes)
U = 12-pulse connection (without chokes)
Figure 3-1. Vacon NX type designation code