vacon
monitoring & parameters
Tel. +358 (0)201 2121 • Fax +358 (0)201 212205
5
V2.1
Communication status
14014
Status of Modbus
communication.
Format:
XXXX.Y, X
= DeviceNet
msg counter
Y
= DeviceNet status
0
= Non-existent or no
bus power
1
= Configuring state
2
= Established
3
= Timeout
P2.2
Output assembly type
20
111
21
14012
20, 21, 23, 25, 101, 111
P2.3
MAC ID
0
63
63
14010
P2.4
Baud rate
1
3
1
14011
1
= 125 kbit/s
2
= 250 kbit/s
3
= 500 kbit/s
P2.5
Input assembly type
70
117
71
14013
70, 71, 73, 75, 107,
117
When the ProfidBus E3/E5 board is installed, the comm. parameters are as follows
V2.1
Communication status
14022
V2.2
Fieldbus protocol status
14023
V2.3
Active protocol
14024
V2.4
Active baud rate
14025
V2.5
Telegram type
14027
P2.6
Operate mode
1
3
1
14021
1
= Profidrive
2
= Bypass
3
= Echo
P2.7
Slave address
2
126
126
14020
When the OPT-BH board is installed, the comm. parameters are as follows
P2.1
Sensor 1 type
0
6
0
14072
0
= No Sensor
1
= PT100
2
= PT1000
3
= Ni1000
4
= KTY84
5
= 2 x PT100
6
= 3 x PT100
Code
Parameter
Min
Max Default
ID
Note
Table 20: System parameters