monitoring & parameters
vacon
•
21
24-hour s358 (0)201 212 575 • Email: [email protected]
5
5. MONITORING AND PARAMETERS
NOTE! This guide is for the standard application of Vacon 20. If you need detailed
parameter descriptions, please download the user manual from www.vacon.com
-> Support & downloads.
5.1 Monitoring values
Code
Monitoring signal
Unit
ID
Description
V1.1
Output frequency
Hz
1
Output frequency to motor
V1.2
Frequency reference
Hz
25
Frequency reference to motor con-
trol
V1.3
Motor speed
rpm
2
Calculated motor speed
V1.4
Motor current
A
3
Measured motor current
V1.5
Motor torque
%
4
Calculated actual/nominal motor
torque
V1.6
Motor shaft power
%
5
Calculated actual/nominal motor
power
V1.7
Motor voltage
V
6
Motor voltage
V1.8
DC link voltage
V
7
Measured DC link voltage
V1.9
Unit temperature
°C
8
Heatsink temperature
V1.10
Motor temperature
%
9
Calculated motor temperature
V1.11
Output power
KW
79
Output power from drive to motor
V2.1
Analog input 1
%
59
AI1 signal range as percent of used
range
V2.2
Analog input 2
%
60
AI2 signal range as percent of used
range
V2.3
Analog output
%
81
AO signal range as percent of used
range
V2.4
Digital input status DI1,
DI2, DI3
15
Digital input status
V2.5
Digital input status DI4,
DI5, DI6
16
Digital input status
V2.6
RO1, RO2, DO
17
Relay/digital output status
V2.7
Pulse train/encoder
input
%
1234
0 - 100% scale value
V2.8
Encoder rpm
rpm
1235
Scaled according to encoder
pulses/revolution parameter
Table 1: Monitoring values
Содержание 20
Страница 1: ...vacon 20 ac drives quick guide...
Страница 2: ......
Страница 15: ...installation vacon 13 24 hour support 358 0 201 212 575 Email vacon vacon com 2 2 3 4...
Страница 16: ...14 vacon installation Tel 358 0 201 2121 Fax 358 0 201 212205 2 5 6...