general data
vacon
•
55
24-hour s358 (0)201 212 575 • Email: [email protected]
7
EMC
Immunity
Complies with EN50082-1, -2, EN61800-3
Emissions (see
detailed descrip-
tions in Vacon 20
User Manual at
www.vacon.com)
230 V: complies with EMC category C2; with internal RFI filter.
MI4 and 5 comply with C2; with optional DC choke and CM choke.
400V: Complies with EMC category C2; with internal RFI filter.
MI4 and 5 comply with C2; with optional DC choke and CM choke.
Both: No EMC emission protection (Vacon level N); without RFI filter.
Standards
For EMC: EN61800-3,
For safety: UL508C, EN61800-5
Certifi-
cates and
manufac-
turer’s dec-
larations of
conformity
For safety: CE, UL, cUL, KC
For EMC: CE, KC
(see unit nameplate for more detailed approvals)
Cable and fuse
requirements
(see detailed data
in Vacon 20 User
Manual at
www.vacon.com)
380 - 480 V, 3~
208 - 240 V, 3~
Frame
Fuse (A)
Mains cable
Cu (mm
2
)
Terminal cable min-max
(mm
2
)
Main
Earth
Control
and relay
MI1
6
3*1.5+1.5
1.5-4
0.5-1.5
MI2
10
MI3
20
3*2.5+2.5
1.5-6
MI4
20
25
40
(20 and 40 is
only for 208 -
240 V, 3~)
3*6+6
1-10
Cu
1-10
MI5
40
3*10+10
2.5-50
Cu/Al
2.5-35
115 V, 1~
MI2
20
2*2.5+2.5
1.5-4
MI3
32
2*6+6
208 – 240, 1~
MI1
10
2*1.5+1.5
MI2
20
2*2.5+2.5
MI3
32
2*6+6
1.5-6
600 V
MI3
6
3*1.5+1.5
1.5-4
MI3
10
MI3
20
3*2.5+2.5
1.5-6