Parameter description
vacon • 42
Service support: find your nearest Vacon service center at www.vacon.com
3
3.5
Input functions
P5.1
S
TART
SIGNAL
1
P5.2
S
TART
SIGNAL
2
Signals for start and direction. Logic is selected with P2.1.
0: Function not used
1: ASi Output 1
2: ASi Output 2
3: ASi Output 3
4: ASi Output 4
5: Sensor 1
6: Sensor 2
7: Sensor 3
8: Sensor 4
P5.3
P
RESET
SPEED
BIT
0
P5.4
P
RESET
SPEED
BIT
1
P5.5
P
RESET
SPEED
BIT
2
Signals for preset speed selection, with binary coding.
P5.6
F
AULT
RESET
Active on rising edge.
Note: an automatic fault reset is triggered when Manual mode is activated on operator panel.
P5.7
F
ORCE
BRAKE
Signal high opens the mechanical brake.
Required action
Activated frequency
B2
B1
B0
Preset frequency 0
B2
B1
B0
Preset frequency 1
B2
B1
B0
Preset frequency 2
B2
B1
B0
Preset frequency 3
B2
B1
B0
Preset frequency 4
B2
B1
B0
Preset frequency 5
B2
B1
B0
Preset frequency 6
B2
B1
B0
Preset frequency 7
Table 45. Selection of preset frequencies;