9.1.2
MAINS VOLTAGE 380-500 V
Table 46: The power ratings of Vacon
®
100 FLOW in mains voltage 380-500 V, 50-60 Hz, 3~
Frame
Drive type
Loadability *
Motor shaft power
Continuous
current I
L
[A]
Input
current I
in
[A]
10%
overload
current [A]
Max
current I
S
2s
400 V
mains
480 V
mains
10%
overload
40°C [kW]
10%
overload
40°C [hp]
MR4
0003
3.4
3.4
3.7
5.2
1.1
1.5
0004
4.8
4.6
5.3
6.8
1.5
2.0
0005
5.6
5.4
6.2
8.6
2.2
3.0
0008
8.0
8.1
8.8
11.2
3.0
4.0
0009
9.6
9.3
10.6
16.0
4.0
5.0
0012
12.0
11.3
13.2
19.2
5.5
7.5
MR5
0016
16.0
15.4
17.6
24.0
7.5
10.0
0023
23.0
21.3
25.3
32.0
11.0
15.0
0031
31.0
28.4
34.1
46.0
15.0
20.0
MR6
0038
38.0
36.7
41.8
62.0
18.5
25.0
0046
46.0
43.6
50.6
76.0
22.0
30.0
0061
61.0
58.2
67.1
92.0
30.0
40.0
MR7
0072
72.0
67.5
79.2
122.0
37.0
50.0
0087
87.0
85.3
95.7
144.0
45.0
60.0
0105
105.0
100.6
115.5
174.0
55.0
75.0
MR8
0140
140.0
139.4
154.0
210.0
75.0
100.0
0170
170.0
166.5
187.0
280.0
90.0
125.0
0205
205.0
199.6
225.5
340.0
110.0
150.0
MR9
0261
261.0
258.0
287.1
410.0
132.0
200.0
0310
310.0
303.0
341.0
502.0
160.0
250.0
* = See chapter 9.1.5 Overload capability.
TECHNICAL DATA, VACON® 100 FLOW
VACON · 135
24-HOUR S358 (0)201 212 575 · EMAIL: [email protected]
9
Содержание 100 flow
Страница 1: ...vacon 100 vacon 100 flow vacon 100 hvac ac drives installation manual wall mounted drives ...
Страница 2: ......
Страница 4: ...VACON 4 TEL 358 0 201 2121 FAX 358 0 201 212 205 ...
Страница 78: ...3 Remove the cable cover M4x8 MR8 M4x8 MR9 VACON 78 POWER CABLING 5 TEL 358 0 201 2121 FAX 358 0 201 212 205 ...