DE35-ST Operating Instructions
D292469I
59
+/- Keys
Pressing the
+/-
keys with the Pick Arm in the wait position will move
the arm to the last placement position on the waffle pack.
Once the arm has moved to this position, the
+
key will move the arm
forward
through each pocket of the current waffle pack until it reaches
the
last
pocket. It will then move to the first position of the next
waffle pack.
The
-
key will do the opposite, moving the arm
backward
through each pocket of
the current waffle pack until it reaches the
first
pocket. It will then move to the
last pocket of the previous waffle pack.
NOTE:
The die count will be incremented each time the
+
key is depressed and
decremented each time the
–
key is depressed. The pocket that the tip is left in
will be the next pocket the die will be placed to when the foot pedal is pressed.
The die will then be placed in order from that position and the die count will be
adjusted.
Eject Test
Pressing the
Eject Test
key will eject the Eject Head needles.
Pressing this key again will retract the needles. If you are unsure if
the needles are ejected, pressing
NO
always retract the needles in
RUN Mode
.
Arm Load/Unload
Pressing
Arm Load/Unload
will move the arm left or right,
depending on where the arm is positioned when pressed.
If the arm is in the
Wait Position
, pressing this key will move the arm left to the
Pick Position
. Pressing this key again will cause the arm to move right, seeking its
Home Position
. Continued pressing of this key will cycle the arm through various
positions, depending on the options on the machine, until it seeks its
Home
Position
again.
When
Arm Load/Unload
is pressed, the last placement position and die count
are remembered. This function is helpful when the arm needs to be moved out
of the way to replace a wafer in the Wafer Holder, waffle packs on the Output
Plate, or if the arm has run into something and has lost position.
When using Grades, pressing
Arm Load/Unload
after placing a die will move the
table out to the
Load/Unload Position
allowing that tray to be replaced without
affecting the count of the other grades.
Содержание Royce DE35-ST
Страница 2: ...2 D292469I BLANK PAGE...
Страница 26: ...DE35 ST Operating Instructions D292469I 25 BLANK PAGE...
Страница 45: ...44 D292469I BLANK PAGE...
Страница 57: ...56 D292469I BLANK PAGE...
Страница 83: ...82 D292469I NOTE The Die Ejector is automatically switched off after about 1 minute...
Страница 95: ...94 D292469I Blank Page...
Страница 107: ...106 D292469I Blank Page...
Страница 130: ...DE35 ST Operating Instructions D292469I 129 Blank Page...
Страница 132: ...DE35 ST Operating Instructions D292469I 131 Blank Page...
Страница 134: ...DE35 ST Operating Instructions D292469I 133 Blank Page...