SETTING PROCEDURE
The alarm system has various setting modes, some of which are EN50131 compliant.
Compliant with EN50131:
setting with keypad, through time scheduler and through a customised key input.
Not compliant with EN50131:
setting with electronic or proximity key, remote activation via PSTN module (available only with
1068/005 control panel), GMS module or IP module and radio remote control.
The authorisation codes which must be used with keypads are described in
paragraph 5.1 System access codes.
You can activate the entire system and only a few zones if they have been configured in programming.
The User or key must have been previously assigned to the zone during programming in order to operate on it.
2.3.1
Partial or total setting with 1068/021 keypad
System setting can be:
Total
Partial
2.3.1.1
Enabling direct setting
Quick direct setting is used to make the system operational without entering a code.
If the specific function is enabled, the system can be activated using the quick setting keys.
Proceed as follows to enable the function:
1.
Access the
MASTER
/
INSTALLER
menu by entering the access code. Press
to confirm;
2.
Select "
Keypad settings
" by pressing the key associated with the
or
symbol. Press
to confirm;
3.
Select "
Direct setting
" by pressing the key associated with the
or
symbol. Press
to confirm;
4.
Press the key
associated with the "ACTIVATION" message
on the display:
o
“ENABLE”
: direct setting enabled.
o
“ENABLE” : direct setting NOT enabled.
5.
Press
to confirm;
6.
Press
repeatedly to go back to the upper level menu.
2.3.1.2
Configuration of partial setting quick keys
The
A / B / C
quick setting keys will only work if they have been previously programmed.
Proceed as follows to configure the function:
1.
Access the
MASTER
/
INSTALLER
menu by entering the access code. Press
to confirm;
2.
Select "
Keypad settings
" by pressing the key associated with the
or
symbol. Press
to confirm;
3.
Select "
A / B / C keys
" by pressing the key associated with the
or
symbol. Press
to confirm;
4.
Select "
A key
" by pressing the key associated with the
or
symbol. Press
to confirm;
5.
Select the zone “
ZNXX : Zone X
" by pressing the key associated with the
or
symbol.
6.
Press the key
associated with the "ASSIGNMENT" message
on the display:
o
“ZN0X: Zone X”
: zone associated with key A
o
“ZN0X: Zone X” : zone NOT associated with key A
Press
to confirm;
7.
Perform the assignment operation for all zones you want to assign to key A;
8.
Perform operations from Step 4 for all
A
/
B
/
C
keys;
9.
Press
repeatedly to go back to the upper level menu.
2.3.1.3
Quick total setting
Proceed as follows to set the alarm system:
1.
Press the key
associated with the symbol
to activate the intrusion alarm system.
2.
If "direct setting" is enabled:
If there are programmed subzones ("
A
" / "
B
" / "
C
") - select the key
associated with the symbol
again.
If there are no programmed subzones ("
A
" / "
B
" / "
C
") the system will be directly activated.
3.
If "direct setting" is not enabled:
If there are programmed subzones ("
A
" / "
B
" / "
C
") - select the key
associated with the symbol
again. You will be
asked to enter a user code, enter the code and press
to confirm.
If there are no programmed subzones ("
A
" / "
B
" / "
C
") you will be asked to enter a user code immediately.
Enter the code and press
to confirm.
IMPORTANT!
With this procedure a user will set only the relevant zones filtered by zones assigned to the keypad and not
necessarily all of them.
The user (MASTER / INSTALLER / TECH. MANAGER) activates all the zones without being filtered by the keypad zones
assignment.