digiset
5
Urma AG, Switzerland www.urma.ch
page 43
8.2.2 Maximum
The measuring lines are created on the contour of the object to be measured. Both
adjustment bars are hidden. The offset of the measuring lines and the fixed cross
hairs in the X and Z direction is taken into account with the current position.
You access this operating mode using the following menu steps:
Main menu
Sub-menu 1
Imaging
Ö
Maximum
After selection the system analyses the object contour and automatically suggests a
measuring procedure for carrying out the measurements immediately. The measuring
procedure used is displayed in the status window at the same time. If an alternative
measuring method is required it is possible to enter the measuring procedure manu-
ally by pressing the button.
Procedure:
1. Move the object into the camera’s visual range.
2. If the relevant contour of the object is not clear, select the "Range" operating
mode and, using the mouse, make it the required size and drag it round the
relevant edge.
3. Select the operating mode as described above.
4. Turning the object to be measured on its support sets the greatest deviation.
5. While the object is being turned the test LED turns green as soon as the
measurement is correct, i.e. the greatest deviation has been determined.
You must ensure here that the turning speed is not too great. When the
measurement has been made correctly the offset values are saved and
transferred through the serial port.
6. If the object is set to a specific size, the object must be moved again to the
greatest deviation position so that the arrow of the adjustment bar corre-
sponding to the deviation direction is in the green area again.
7. Then the unit switches to the "Preset" measuring method.
)