Closed loop system
Operation of
EV1
Operation of
EV2
Humidity
Measurement
figure 5
Closed- loop system in STEAM.Maxi™
STEAM.Maxi
TM
set to 100%
First class
Dry
conditions
Saturated
conditions
Penultimate
class
Last
class
■ If the relative humidity measurement, Hm, does not fall into the penultimate class, the quantity of steam
is increased by 20% .
■ If the relative humidity measurement, Hm, is 100% o r if the four consecutive measurements of humidity
fall into the penultimate class, the quantity of steam is reduced by 20% .
In case of Humidity Measurement parameter set to ON, the timing of the opening of the solenoid valves
is proportional to the difference between the humidity value set point, Hsp and the relative humidity
value measured, Hm.
Therefore, the steam tables are chosen according to this feedback control, figured in
Figure 5.
When STEAM.Maxi™ is set to 100%, the system records the number of consecutive times in which the
cooking chamber has reached the saturation level. If this value is 3, the system switches off the steam
solenoids to provide the steam table of 5% according to the oven model.
Assumption
: For a specific temperature, the range of RPM between dry conditions and saturated
conditions (calculated during the humidity calibration) is subdivided into a specific number of classes.
For each class, a number of RPM and a specified humidity amount have been defined
RPM gap measured during the humidity
regulation at a specific Temperature
Figure 6
Classes of RPM defined at a specific temperature
In the case of STEAM.Maxi™ set to 100%, the oven starts producing a quantity of steam which
corresponds to the value of 100% of the oven steam table. Once the first measurement of the humidity
has been done, the quantity of steam is increased or decreased by 20% according to the following rules:
68
Содержание MINDMaps BAKERTOP
Страница 1: ...SERVICE MANUAL...
Страница 134: ...Figure 3 test Other visual checks 1 Cooling fan is running 2 Motors stuck by the shaft 3 External heat source OVEN 134...
Страница 138: ...OVEN Test to do Test 1 138...
Страница 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Страница 141: ...go to INDEX OVEN Test to do Light ON Light OFF Normal power board status AF04 power board status 141...
Страница 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Страница 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Страница 161: ...Test to do test 1Measurethemotorpowersupply from the power baord OVEN test 2Measure the RPM on the P20 socket 161...
Страница 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Страница 167: ...OVEN Low pressure status High pressure status Low pressure status High pressure status Test 2 Test 3 167...
Страница 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Страница 215: ...214...