wF01 - wF02 CHaMber teMPerature Probe
Measure the
impedance of the probe
with the multimeter set
to ohm
Replace the
temperature probe
and test the oven at
over 200 °C (392 °F)
End
Is chamber
probes 1 or 2
connected to
the power
board?
Connect the probe
to the power board
WF01 / WF02
temperature probe
warning
Replace the power
board
Do you
measure 110 ohm
at about
25 °C (77°F)?
Does the alarm
persist?
YES
YES
YES
Test 1
NO
NO
NO
test 1
Measure the impedance of the probe
OvEN