table 1
Other than the 3P + N + PE 380 – 400 V connection in the DTC, other electrical connection are shown. To
perform special connections not written in the DTC, refer to the table below that describes the special kit
on available on request to convert the electrical connection.
Model Id
220-240 V ~3PH+Pe
recommended size
Cu 90°C
CIrCUIT BrEAKEr
I
l1
[A]
I
l2
[A]
I
l3
[A]
[mm
2
]
[A]
XECC-1013-EPxM
45,5
47,5
47,5
10
50
XEVC-1011-EPRxM
XEVC-1011-E1RxM
XEVC-1011-EZRxM
45,5
47,5
47,5
10
50
XEBC-10EU-EPxM
XEBC-10FS-EPxM-AL
51
54
54
10
63
XEBC-10EU-E1xM
38,5
37
37
10
50
Model Id
220-240 V ~1PH+N+Pe
recommended size
Cu 90°C
CIrCUIT BrEAKEr
I
l1
[A]
[mm
2
]
[A]
XECC-0513-EPxM
41
10
50
XEVC-0511-EPRxM
XEVC-0511-E1RxM
XEVC-0511-EZRxM
41
10
50
XEVC-0711-EPRxM
XEVC-0711-E1RxM
XEVC-0711-EZRxM
51,5
10
63
XEBC-04EU-EPxM
46,5
10
50
XEBC-06EU-EPxM
XEBC-06FS-EPxM-AL
61,5
10
63
XEBC-06EU-E1xM
43
10
50
The power board supplies 230 V AC to the transformer across the pins NF and LF of the P1 socket. The
primary turn of the transformer is powered at 230 VAC. The secondary turn of the transformer converts the
230 VAC into 12/21 VAC for PLUS models and into only 12 VAC for ONE models.
The F2 fuse (size: 2 A – 250 V, type: Fast Acting) is in between the power board and the transformer primary
turn. When the transformer is shorted, the F2 blows to protect the circuits of the power board.
The power board receives the low voltage from the secondary turn of the transformer into P21 socket. In the
PLUS version, there is normally 12 VAC and 21 VAC across the yellow wires and red wires respectively. In
the ONE version there is only 12 VAC across the yellow wires. The F4 fuse (size: 4 A – 250 V, type: Time
Delayed) is in-between the transformer secondary turn and the power board. When one or more low
voltage components are shorted, the F4 fuse blows to protect the secondary turn of the transformer, see
Figure 2
.
Power
Board
F2
230V AC
12/21 V AC
12 Vac (only for
PE2037A0)
Power
Board
F4
230V AC
12/21 V AC
12 V AC (only for PE2037A0)
PCB
PCB
Figure 2
Electrical oven electrical scheme
9
Содержание MINDMaps BAKERTOP
Страница 1: ...SERVICE MANUAL...
Страница 134: ...Figure 3 test Other visual checks 1 Cooling fan is running 2 Motors stuck by the shaft 3 External heat source OVEN 134...
Страница 138: ...OVEN Test to do Test 1 138...
Страница 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Страница 141: ...go to INDEX OVEN Test to do Light ON Light OFF Normal power board status AF04 power board status 141...
Страница 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Страница 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Страница 161: ...Test to do test 1Measurethemotorpowersupply from the power baord OVEN test 2Measure the RPM on the P20 socket 161...
Страница 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Страница 167: ...OVEN Low pressure status High pressure status Low pressure status High pressure status Test 2 Test 3 167...
Страница 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Страница 215: ...214...