wC05 – FuMeS teMPerature warNiNG
HOOd
NO
Open the tap
YES
NO
YES
Replace the water
solenoid valve
NO
Replace the
temperature probe
YES
YES
WC05 fumes
temperature
Is the water
tap open?
Measure with
the multimeter set
to V AC if the power
board provides 230 V AC
to the connector of the water
solenoid valve. Is the
solenoid
power on?
Replace the hood
power board
NO
NO
Replace the hood
power board
Does the
flow
of water cross the water
solenoid valve ? (Check if you
ear the flux of water out of the
hood drain)
Measure the
impedance of the
temperature probe with the
multimeter set to ohm.
Do you have 110 ohm
at 25 °C (77 °F)?
191
Содержание MINDMaps BAKERTOP
Страница 1: ...SERVICE MANUAL...
Страница 134: ...Figure 3 test Other visual checks 1 Cooling fan is running 2 Motors stuck by the shaft 3 External heat source OVEN 134...
Страница 138: ...OVEN Test to do Test 1 138...
Страница 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Страница 141: ...go to INDEX OVEN Test to do Light ON Light OFF Normal power board status AF04 power board status 141...
Страница 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Страница 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Страница 161: ...Test to do test 1Measurethemotorpowersupply from the power baord OVEN test 2Measure the RPM on the P20 socket 161...
Страница 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Страница 167: ...OVEN Low pressure status High pressure status Low pressure status High pressure status Test 2 Test 3 167...
Страница 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Страница 215: ...214...