wC02 – Power board oVer teMPerature
HOOd
YES
Replace the hood
power board
NO
NO
YES
NO
Open the tap
YES
NO
Replace the hood
power board
YES
NO
Replace the water
solenoid valve
YES
Replace the hood
power board
WC02 power
board over
temperature
Let the hood
cool down. Is the warning
message still
displayed?
Has the
hood been
installed following
UNOX guidelines?
Is the
water tap
open?
Install the hood
following The installation
manual on ddc-
service.com
Measure with
the multimeter
set to V AC if the power
board provides 230 V AC
to the connector of the
water solenoid valve.
Is the solenoid
power on?
Does the
flow
of
water cross the solenoid valve?
(Check if you ear the flux of
water out of the
hood drain)
190
Содержание MINDMaps BAKERTOP
Страница 1: ...SERVICE MANUAL...
Страница 134: ...Figure 3 test Other visual checks 1 Cooling fan is running 2 Motors stuck by the shaft 3 External heat source OVEN 134...
Страница 138: ...OVEN Test to do Test 1 138...
Страница 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Страница 141: ...go to INDEX OVEN Test to do Light ON Light OFF Normal power board status AF04 power board status 141...
Страница 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Страница 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Страница 161: ...Test to do test 1Measurethemotorpowersupply from the power baord OVEN test 2Measure the RPM on the P20 socket 161...
Страница 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Страница 167: ...OVEN Low pressure status High pressure status Low pressure status High pressure status Test 2 Test 3 167...
Страница 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Страница 215: ...214...