OvEN
wF25 - water ValVe el2
KVL1101A (KVL1104A for US version)
Single rotor arm PLUS cleaning system
KVL1103A (KVL1105A for US version)
Double rotor arm PLUS cleaning system
Detergent filter
with not return
valve
Detergent filter
with not return
valve
Non-return
valve
Non-return
valve
EL1436A, EL1
EL1436A, EL1
EL1426A, EG1
EL1426A, EG1
EL1426A, EG2
EL1422A, EL2
Vibration
pump
Pressure
switch
(NO)
EL1422A, EL2
Vibration
pump
Pressure
switch
(NO)
WF25 EL1 or EL2
valve
NO
Replace the power
board
Test 1
EL1 does not close or
EL2 does not open
YES
YES
Replace the power
board
Replace the EL1
valve
Replace the EL2
valve
Test 3
NO
Does the alarm
disapear?
YES
End
NO
Replace the
pressure switch
YES
Replace the power
board
EL2 is the most probable
cause of this alarm
Measure with the
mulmeter set to voltage if the
power board supplies 230 V AC to
the connector of the water solenoid.
Do you have the supplied
on the EL2?
Measure with the
mulmeter set to voltage if
the power board supplies 230 V AC to the
connector of the water solenoid.
Do you have the supplied
on the EL1?
Test if the
pressure switch opens
the circuit with the mulmeter
set to ohm. Does
it open the
circuit?
KVL1101A (KVL1104A for US version)
Single rotor arm PLUS cleaning system
KVL1103A (KVL1105A for US version)
Double rotor arm PLUS cleaning system
Detergent filter
with not return
w
valve
Detergent filter
with not return
valve
Non-return
valve
Non-return
valve
EL1436A, EL1
EL1436A, EL1
EL1426A, EG1
E
EL1426A, EG1
EL1426A, EG2
EL1422A, EL2
Vibration
pump
Pressure
switch
(NO)
EL1422A, EL2
Vibration
pump
Pressure
switch
(NO)
WF25 EL1 or EL2
valve
NO
O
O
Replace the power
board
Test 1
EL1 does not close or
EL2 does not open
YES
YES
Replace the power
board
Replace the EL1
valve
Replace the EL2
valve
Test 3
NO
O
Does the alarm
disapear?
YES
End
NO
Replace the
pressure switch
YES
Replace the power
board
EL2 is the most probable
cause of this alarm
Measure with the
mulmeter set to voltage if the
power board supplies 230 V AC to
the connector of the water solenoid.
Do you have the supplied
on the EL2?
Measure with the
mulmeter set to voltage if
the power board supplies 230 V AC to the
connector of the water solenoid.
Do you have the supplied
Do you have the supplied
on the EL1?
Test if the
pressure switch opens
the circuit with the
mulmeter
set to ohm. Does
it open the
circuit?
Update software with
the latest version available
and run a washing program
SUSPENDED
174
Содержание MINDMaps BAKERTOP
Страница 1: ...SERVICE MANUAL...
Страница 134: ...Figure 3 test Other visual checks 1 Cooling fan is running 2 Motors stuck by the shaft 3 External heat source OVEN 134...
Страница 138: ...OVEN Test to do Test 1 138...
Страница 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Страница 141: ...go to INDEX OVEN Test to do Light ON Light OFF Normal power board status AF04 power board status 141...
Страница 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Страница 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Страница 161: ...Test to do test 1Measurethemotorpowersupply from the power baord OVEN test 2Measure the RPM on the P20 socket 161...
Страница 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Страница 167: ...OVEN Low pressure status High pressure status Low pressure status High pressure status Test 2 Test 3 167...
Страница 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Страница 215: ...214...