rOTOr.KLEAN
TM
Introduction
A
D
E
B-C
water iNlet SySteM aFter February 2020
The water inlet system is composed of:
A) Input filter 3/4’’ with non-return valve + mechanical filter of
100 μm;
B) One pressure reducer set at 2.3 bar / 29 psi ) (not adjustable);
C) One water main connection pipe made of white LDPE (de
= 10 mm - 0,4 inches);
D) Cleaning system fed by the blue pipe made of EPDM (de =
12 mm - 0,31 inches);
E) Black pipe for steam EPDM (de = 12 mm - 0.31 inches);
F ) Connection to the detergent tank black LDPE (de = 10 mm
- 0,4 inches).
figure 9
Water inlet after February 2020
water iNlet SySteM beFore deCeMber 2016 (see Figure 1)
The water inlet system is composed of:
A) Input filter 3/4’’ with non-return valve;
B) One mechanical filter of 100 μm;
C) One pressure reducer set at 2.3 bar / 29 psi ) (not adjustable);
D) One water main connection pipe made of white LDPE (de = 10 mm - 0,4 inches);
E) Cleaning system fed by the blue pipe made of LDPE (de = 8 mm - 0,31 inches);
F) White pipe for steam LDPE (de = 8 mm - 0.31 inches);
G) Connection to the detergent tank black LDPE (de = 10 mm - 0,4 inches).
ø10 D
ø10
B-C
ø8 E
ø10 G
ø8 F
ø8 F
A
ø8 E
ø10 G
Figure 10
Water inlet before December 2016
Self cleaning solenoid valves
74
Содержание MINDMaps BAKERTOP
Страница 1: ...SERVICE MANUAL...
Страница 134: ...Figure 3 test Other visual checks 1 Cooling fan is running 2 Motors stuck by the shaft 3 External heat source OVEN 134...
Страница 138: ...OVEN Test to do Test 1 138...
Страница 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Страница 141: ...go to INDEX OVEN Test to do Light ON Light OFF Normal power board status AF04 power board status 141...
Страница 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Страница 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Страница 161: ...Test to do test 1Measurethemotorpowersupply from the power baord OVEN test 2Measure the RPM on the P20 socket 161...
Страница 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Страница 167: ...OVEN Low pressure status High pressure status Low pressure status High pressure status Test 2 Test 3 167...
Страница 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Страница 215: ...214...