Input
NAME
INpUT
dESCrIpTION
INpUT TypE
rANgE
SENSITIv-
ITy
prECISION HArdWArE
INpUT
CMB_1
Bottom temperature probe
Analogue PT100 0 – 300 °C
0.1°C
+/- 0.5 °C
√
CMB_2
Top temperature probe
Analogue PT100 0 – 300 °C
0.1°C
+/- 0.5 °C
√
BRD_TEMP
Board temperature probe
Analogue NTC
0 – 100 °C
5°C
+/- 5 °C
HEART_1 Single point core probe or 1st multi
point core probe point
Analogue PT100 0 – 300 °C
0.1°C
+/- 0.5 °C
√
HEART_2
2nd multi point core probe point
Analogue PT100 0 – 300 °C
0.1°C
+/- 0.5 °C
√
HEART_3
3rd multi point core probe point
Analogue PT100 0 – 300 °C
0.1°C
+/- 0.5 °C
√
HEART_4
4th multi point core probe point
Analogue PT100 0 – 300 °C
0.1°C
+/- 0.5 °C
√
TAC_1
Tachometer group 1 (speed)
Analogue
30 – 10K
RPM
1 RPM
+/- 1 RPM
√
TAC_2
Tachometer group 2 (direction)
Analogue
30 – 10K
RPM
1 RPM
+/- 1 RPM
√
VAC
Power supply alternate current
Analogue
0 – 260 V
RMS
1 V
+/- 5 V
IAC_MOT
Motor power supply alternate
current
Analogue
0 - 8 A
RMS
1 mA
RMS
+/- 50 mA
RMS
IAC_LOAD
Auxiliary loads power supply
alternate current
Analogue
0 - 1.5 A
RMS
1 mA
RMS
+/- 5 mA
RMS
VDC
V DC on modbus
Analogue
0 – 15 V
1 mV
+/- 20mV
IDC
DC current
Analogue
0 – 7 A
1 mA
+/- 5mA
AC_FREQ
Power supply frequency
Analogue
0 - 50 - 60
Hz
-
-
MOTDIR_1
Motor revolution direction
(TAC1-TAC2)
Digital
-
-
-
MOTDIR_2 Motor revolution direction
(TAC3-TAC4)
Digital
-
-
-
DOOR_1
Door switch 1
Digital
-
-
-
√
DOOR_2
Door switch 2 (trolley switch)
Digital
-
-
-
√
ALL_TS
Safety thermostat alarm
Analogue
-
-
-
ALL_TM
Motor thermal protection
Digital
-
-
-
INCP_1
Potential free contact 1
Digital
-
-
-
√
INCP_2
Potential free contact 2
Digital
-
-
-
√
INCP_3
Potential free contact 3
Digital
-
-
-
√
IN_PRES
Pressure switch
Digital
-
-
-
√
EV_GAS
Gas Valve feeding
Digital
-
-
-
√
TAC_BLW_1
Premix blower tachimetric 1
Analogue
30 – 10K
RPM
1 RPM
+/- 1 RPM
√
TAC_BLW_2
Premix blower tachimetric 2
Analogue
30 – 10K
RPM
1 RPM
+/- 1 RPM
√
32
Содержание MINDMaps BAKERTOP
Страница 1: ...SERVICE MANUAL...
Страница 134: ...Figure 3 test Other visual checks 1 Cooling fan is running 2 Motors stuck by the shaft 3 External heat source OVEN 134...
Страница 138: ...OVEN Test to do Test 1 138...
Страница 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Страница 141: ...go to INDEX OVEN Test to do Light ON Light OFF Normal power board status AF04 power board status 141...
Страница 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Страница 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Страница 161: ...Test to do test 1Measurethemotorpowersupply from the power baord OVEN test 2Measure the RPM on the P20 socket 161...
Страница 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Страница 167: ...OVEN Low pressure status High pressure status Low pressure status High pressure status Test 2 Test 3 167...
Страница 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Страница 215: ...214...