Terminal ER
Ionization probe
Microammeter DC
uA > 2-3 times the minimum one
Example with 0,5 μA: μA>1,5 μA
+
-
μA
this procedure is applicable only to the flame control plug.
■ Disconnect the terminal of the flame control electrode as shown in
Figure 20
;
■ Connect the multimeter in series as described above by means of the two cables with the crocodile
clamp to one of the flame control electrodes and to one of the internal metallic part of the terminal of
the cable, as shown in
Figure 21
;
Ionization current measurements
The ionization flame detection device makes use of the rectification property of the flame (ionization), as
shown in
Figure 19
. The control system is more sensitive to the flame at starting or during waiting/prepurge
time (negative differential switching).
Figure 19
Ionization flame scheme
The ground terminal of the control system, the metal frame of the gas burner and the ground on the main
supplies must have a good connection. Avoid putting the detection cable close to power or ignition cables.
In case of “partial” short circuits or bad insulation between signal and ground the voltage on the detection
electrode can be reduced making it impossible to detect the flame signal, resulting in a lockout of the
control system. In order to measure the ioniziation current, the multimeter has to be connected in series
between the flame control electrode and the flame control board. The value of the current measured
should be in the range of 1.5 - 10 μA.
Figure 20
Flame control plug and flame control plug cable
Figure 21
Multimeter connection to the flame control plug
121
Содержание MINDMaps BAKERTOP
Страница 1: ...SERVICE MANUAL...
Страница 134: ...Figure 3 test Other visual checks 1 Cooling fan is running 2 Motors stuck by the shaft 3 External heat source OVEN 134...
Страница 138: ...OVEN Test to do Test 1 138...
Страница 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Страница 141: ...go to INDEX OVEN Test to do Light ON Light OFF Normal power board status AF04 power board status 141...
Страница 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Страница 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Страница 161: ...Test to do test 1Measurethemotorpowersupply from the power baord OVEN test 2Measure the RPM on the P20 socket 161...
Страница 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Страница 167: ...OVEN Low pressure status High pressure status Low pressure status High pressure status Test 2 Test 3 167...
Страница 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Страница 215: ...214...