7HOLD FUNCTION
67
• Timing Chart
t1
:
Time from when the hold signal is inputted to when the indicated value is
held
t2
:
Time from when the hold signal is cancelled to when the indicated value
returns to tracking
t3
:
Minimum reset signal width required for canceling the hold
t2
t3
Detection/Hold Section
Time
Detection/Hold
t1
t2
t1
t3
OFF
ON
Hold
Indicated value
Sensor input value
t1 to
t3 : MAX 5mS
input
Section
Содержание F320
Страница 1: ...F320 DIGITAL INDICATOR 17 May 2012 Rev 1 07 OPERATION MANUAL...
Страница 14: ...CONTENTS...
Страница 120: ...15 DIMENSIONS Standard 106 15 DIMENSIONS Standard Unit mm...
Страница 121: ...15 DIMENSIONS Standard 107 15 1 Dimensions When the BCO option is equipped Unit mm...
Страница 122: ...15 DIMENSIONS Standard 108 15 2 Dimensions When the DAV DAI option is equipped Unit mm...
Страница 129: ...Unipulse Corporation 9 11 Nihonbashi Hisamatsucho Chuo ku Tokyo 103 0005 Tel 81 3 3639 6120 Fax 81 3 3639 6130...