3.CONNECTION
16
WARNING
• Connect with no power applied because it may cause an electric shock.
• Be aware that the voltage drops depending on the wire thickness and length.
Also, never input AC power source. Doing so will cause a failure.
• Since the F320 has no power switch, install a breaker.
• Be sure to ground the protective ground terminal to prevent electric shocks and failures by
static electricity. (The frame and protective ground terminal are conducted.)
Do not use other screws than that attached to the main body (M4×8 binding-head
machine screw with a toothed washer).
• To take measures against lightning surge, install a lightning surge protector (optionally
available).