6. SETTING OF FUNCTIONS
6-1. High /Low Limit Value
High / Low limit value are functions whereby the high output is turned on when
the indicated value exceeds the high / low output is turned on when it drops
below the low limit.
〈
HIGH/LOW output conditions
〉
• HI
ON:
Indicated value > High limit value
OFF:
Indicated value <= High limit value
• LOW
ON:
Indicated value < Low limit value
OFF:
Indicated value >= Low limit value
• High/Low Limit Output Operation
Time
Indicated value
High limit value
Low limit value
HI
LOW
OFF
ON
OFF
ON