SHB_PNG07.fm
A31003-G2100-S100-2-7620, 03/2014
PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
29
PNG Configuration
Alarm Configuration
7.2.3.1
Non Movement
Activation of the non movement alarm is optional. The non movement alarm is triggered when
the sensors detect that the user has not moved for a defined and configurable period of time.
Table 7-10
Parameter setting for non movement
7.2.3.2
Man Down Alarm
Activation of the man down alarm is optional. The man down alarm is triggered when the sen-
sors detect that the handset is leaning at an incorrect angle for a defined and configurable pe-
riod of time (in other words, the handset is in a non-upright position).
Table 7-11
Parameter setting for man down alarm
Parameter
Setting range
Factory setting
BGR 139
Activation
On/Off
On
At least one autom.
alarm
Response time
10 s ... 900 s
90 s
<= 90 s
Prealarm time
0 s ... 30 s
15 s
5 s ... 15 s
Alarm Signal
On/Off
On
On
Alarm destination
32-digit number
Blank (see Section
7.2.1.1, “Alarm Num-
ber Basis”)
Align with PNEZ
Parameter
Setting range
Factory setting
BGR 139
Activation
On/Off
On
At least one autom.
alarm
Response time
10 s ... 900 s
90 s
<= 90 s
Prealarm time
0 s ... 30 s
15 s
5 s ... 15 s
Alarm Signal
On/Off
On
On
Alarm destination
32-digit number
Blank (see Section
7.2.1.1, “Alarm Num-
ber Basis”)
Align with PNEZ