Sample Configurations
A31003-G2100-S100-2-7620, 03/2014
52
PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
SHB_PNG08.fm
Operation in Gigaset base without PNEZ
8.3
Operation in Gigaset base without PNEZ
A Gigaset base does not support the CLIP function which is required for control calls to the
PNG. Consequently, configuration is only possible for operation without PNEZ. See also Sec-
tion 7.2.1.3, “PNEZ Basis (Number Deleted)”.
The following settings are entered manually using the factory defaults as a basis:
●
Enter the "Alarm Number Basis", in the example: 95000
●
Delete the "PNEZ Basis" (delete automatically generated number)
●
Deactivate the man down alarm (disable activation)
●
Activate the time alarm (enable activation)
●
Set the response time for the time alarm (15 min)
The following is configured automatically:
●
Control port deletion
The following table provides a complete overview of the settings:
>
This configuration does not conform to BGR 139.
Parameter
Active
General Settings:
Alarm Number Basis
Input: 95000
PNEZ Basis
Input: Delete
Alarm Call Count
15
Repeat Alarm Time
4 s
Autom. alarms OFF
No
Signal Off - manual
Off
Signal Off - autom.
On
Transport Time
2 s
Emergency:
Alarm Signal
On
Alarm destination
Automatic: 95000
Table 8-3
Settings in sample configuration 3