PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
15
PNG Configuration
Alarm Configuration
7.2.1
General Settings
The "General Settings" menu item contains the following parameters:
7.2.1.1
Alarm Number Basis
Enter the alarm destination here (maximum 32-digit number). This alarm destination is config-
ured here as a destination number for all alarm types. When an alarm is triggered, the alarm
call is signalled at this configured alarm destination.
If you want certain alarms, suchas, the non movement alarm, to be signalled at another alarm
destination, you can change the alarm destination later in the relevant alarm type’s submenu.
The "PNEZ Basis" parameter is automatically calculated and configured when you define the
"Alarm Number Basis". "PNEZ Basis" is the base number that is used for communication be-
tween PNEZ and PNG-S. See also Section 7.2.1.2, “PNEZ Basis (Number Configured)” and
Section 7.2.1.3, “PNEZ Basis (Number Deleted)”.
Please note:
changing and saving "Alarm Number Basis" always affects all dependent config-
urations. Dependent configurations are the following:
●
All alarm destinations of various alarm types
●
"PNEZ Basis" and the control ports that are dependent on it
Please note:
you must first define the "Alarm Number Basis", then make individual changes to
the alarm destinations of the various alarm types. Then, if necessary, you can configure the in-
dividual "PNEZ Basis" and control ports.
Parameter
Parameter input
for startup
See section:
Alarm Number Basis required
Section 7.2.1.1, “Alarm Number Basis”
PNEZ Basis
adjust to PNEZ if neces-
sary
Section 7.2.1.2, “PNEZ Basis (Number Con-
figured)”
Section 7.2.1.3, “PNEZ Basis (Number Delet-
ed)”
Repeat alarm call
optional
Section 7.2.1.4, “Repeat alarm call”
Repeat Alarm Time
optional
Section 7.2.1.5, “Repeat Alarm Time [sec]”
Transport Time
optional
Section 7.2.1.6, “Transport Time [sec]”
Signal Off - manual
optional
Section 7.2.1.7, “Signal Off - manual”
Signal Off - autom.
optional
Section 7.2.1.8, “Signal Off - autom.”
Autom. alarms OFF
optional
Section 7.2.1.9, “Autom. alarms OFF”
Table 7-2
Parameter overview