PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
8
PNG-S in a HiPath Alarm Signal System (HNA)
3
PNG-S in a HiPath Alarm Signal System (HNA)
The HiPath Alarm System is based on the HiPath Cordless Enterprise CMI 3.0 from CV 330.
The control centre for this PNA system (personal alarm signal system) is the emergency call
receiving centre (PNEZ).
The PNEZ controls the PNG-S and responds to its signals and alarms. The CLIP (Calling line
identification presentation) information in the Setup message is required at connection setup
for PNG-S operation.
The PNEZ triggers a function test for the alarm facilities every time monitoring is activated.
Monitoring is activated by the PNEZ if the function test is successful.
Alarm calls from the PNG-S are sent to the configured alarm destination.
In order to ensure that the alarm calls reach the alarm destination they are repeated until an
alarm recall by the PNEZ has been identified or the set number of call repeats has been
reached. However, there is no guarantee that all alarm calls will reach the programmed desti-
nation. Consequently, the PNEZ checks the communication channels to the PNG-S and estab-
lishes contact with the PNG-S on a cyclical basis. If there are no replies, a technical alarm is
generated in the PNEZ and emergency services are deployed.
Localisation can be performed to pinpoint the position of the handset and the party signalling
the alarm.
During alerting, the PNG-S emits an alarm signal, which is used to pinpoint the individual trig-
gering the alarm more precisely.
The PNEZ is responsible for resetting alarms and deactivating monitoring. In doing so, the
PNEZ checks whether or not deactivation is permitted and checks place of deactivation, for in-
stance, as a criterion.
7
The HiPath alarm signal system supports BGR-139-compliant operation. Ensure
that the permitted values are used when configuring the PNG-S.