PNG Configuration
A31003-G2100-S100-2-7620, 03/2014
20
PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
SHB_PNG07.fm
Alarm Configuration
7.2.1.4
Repeat alarm call
The PNG-S automatically signals the alarm call at the alarm destination. Alarm calls are auto-
matically repeated to ensure reliable signalling.
This parameter is used to set the max. number of alarm calls which the PNG-S should make.
Alarm repetition is stopped if the PNG-S recognises the alarm recall. If an alarm recall is not
recognised, the PNG-S repeats the alarm call a minimum of five times. Then "PNG OFF" is dis-
played on the right display key.
You can initiate alarming signal deactivation by pressing "PNG OFF".
●
With "PNEZ Basis" = Number
Requests for alarming signal deactivation in the PNEZ must be performed by the PNEZ.
●
With "PNEZ Basis" = "blank"
The alarming signal is deactivated immediately. Alarm repetitions are stopped. Monitoring
is switched off. The PNG LED is switched off.
Parameter
Setting range
Factory setting
BGR 139
Repeat alarm call
05 ... 99
15
15
(increase if neces-
sary to improve se-
curity)
Table 7-3
Parameter setting for Repeat alarm call