SHB_PNG07.fm
A31003-G2100-S100-2-7620, 03/2014
PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
37
PNG Configuration
Alarm Configuration
Description of numbers:
Number
Explanation
PNG-S out of service:
Number_1
PNG-S starting function test
Number_2
PNG-S starting monitoring
Number_3
Normal voice call following failed function test (optional)
PNG S in monitoring mode:
Number_4
PNG-S switches monitoring/alerting off
Number_5
PNG-S suspends the configured automatic alarms
(Prerequisite: Autom. alarms OFF = By Control Call)
Number_6
PNG-S activates the suspended automatic alarms
(Prerequisite: Autom. alarms OFF = By Control Call)
PNG-S in alarm state:
Number_4
PNG-S switches monitoring/alerting off
Number_7
PNG-S accepts the alarm recall. Microphone and loudspeaker
are switched on. The PNEZ can listen into the alarm situation and
speak with the party signalling the alarm over the loudspeaker.
The call is disconnected from the PNEZ, but can also be discon-
nected from the handset.
Number_8
PNG-S accepts the alarm recall. Microphone and receiver insert
are switched on. The PNEZ can listen into the alarm situation and
speak with the party signalling the alarm over the receiver inset.
The call is disconnected from the PNEZ, but can also be discon-
nected from the PNG-S. This call ends the automatic alarm repe-
titions.
Number_9
PNG-S accepts the alarm recall. Microphone and receiver insert
are switched on. The call is automatically disconnected from the
PNG-S after a few seconds. This call ends the automatic alarm
repetitions.
Description of numbers (PNG-S functions)
7
You can use the alarm recall function to hear what is going on at the alarm location.
Please inform the individual concerned and secure their authorisation before you ac-
tivate this feature.