PNG Configuration for Gigaset M2 

plus 

and M2 Ex professional, Service Manual

23

   

  

  

PNG Configuration

Alarm Configuration

7.2.1.7

Signal Off - manual

This parameter controls whether the alarm/positioning tone can be manually suppressed on the 
handset to enable the alerting party to communicate with the alarm destination.

Signal Off - manual = On

This configuration parameter allows the alarm/positioning tone to be manually suppressed 
when the handset is in alarm mode. The alarm/positioning tone is suppressed for the du-
ration of the call once the "+/-" key has been briefly pressed. The alerting party can com-
municate with the alarm destination.

The alerting party can always communicate with the alarm destination if alerting is configured 
without an alarm tone.

Table 7-5

Parameter setting for Signal Off - manual

7

This type of operation conforms to BGR 139 if location is guaranteed by the position-
ing system.

Parameter

Setting range

Factory setting

BGR 139

Signal Off - manual

On/Off

On

Depends on the po-
sitioning system im-
plemented

Содержание Gigaset M2 plus professional

Страница 1: ...PNG Configuration for Gigaset M2 plus professional Gigaset M2 Ex professional Service Manual A31003 G2100 S100 2 7620...

Страница 2: ...scriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products An obligation to provid...

Страница 3: ...enu 11 Emergency Key 11 Preventing PNG Configuration Changes 12 Emergency Alarm Deactivation 12 PNG Configuration 13 Overview 13 Alarm Configuration 14 General Settings 15 Emergency Emergency key 26 C...

Страница 4: ...ns are identified The following types of alarms and signals are available Man Down Alarm Non Movement Escape Alarm The integrated motion sensor technology recognises motionlessness detects deviation f...

Страница 5: ...plicable laws in other countries Employees of Unify are bound to safeguard trade secrets and personal data under the terms of the company s work rules A conscientious and responsible approach helps pr...

Страница 6: ...set M2 Ex professional A31003 G2100 U104 7619 Operating Manual HiPath 3000 HiPath 500 Gigaset M2 professional Gigaset M2 plus professional Gigaset M2 Ex professional to HiPath Cordless Office A31003 G...

Страница 7: ...describes how to configure the handset and indicates BGR 139 compliant set tings where applicable Activating the PNG functionality blocks certain handset settings for normal users forinstance PNG Con...

Страница 8: ...that the alarm calls reach the alarm destination they are repeated until an alarm recall by the PNEZ has been identified or the set number of call repeats has been reached However there is no guarante...

Страница 9: ...m call count has been reached or until alarm repetition has been interrupted manually on the handset An alarm recall to confirm the alarm call ending the alarm repeats and possibly the silent mo nitor...

Страница 10: ...re that the alarm calls reach the alarm destination they are repeated until the alarm call count has been reached or until alarm repetition has been interrupted manually on the handset It is not possi...

Страница 11: ...d For information on how to proceed see the Operat ing Manual Operating Manual HiPath 3000 HiPath 4000 Gigaset S310 ISDN professional Personal Alarm Device Gigaset M2 plus professional Gigaset M2 Ex p...

Страница 12: ...itoring LED permanently lit Users can perform emergency alarm deactivation at the handset if they are unable to deacti vate an alarm during handset alerting because the handset was not properly config...

Страница 13: ...gh out as PNA Service PNG configuration menus are protected from unauthorized unintentional changes by the PNG user by means of a five digit PIN code You are requested to enter the PNG service PIN whe...

Страница 14: ...m Configuration menu features the following submenus Menu item Description General Settings General alerting parameters Emergency For configuring the deliberate alarm alarm via the emergency key Non M...

Страница 15: ...nd Section 7 2 1 3 PNEZ Basis Number Deleted Please note changing and saving Alarm Number Basis always affects all dependent config urations Dependent configurations are the following All alarm destin...

Страница 16: ...g the following formula PNEZ Basis Alarm Number Basis 10 Example enter the following as the Alarm Number Basis 52200 The PNEZ Basis is cal culated as 52210 and pre configured If you want to change the...

Страница 17: ...utomatically preset Recommendation for BGR 139 configuration Alarm destinations and control ports must be synchronised between PNEZ and the handset Use the handset s automatic configuration function w...

Страница 18: ...reset to Recommendation for BGR 139 configuration Alarm destinations and control ports must be synchronised between PNEZ and the handset Use the handset s automatic configuration function whenever pos...

Страница 19: ...m calls PNG OFF is dis played on the right display key Monitoring is deactivated after resetting PNG activation in the Add Features PNG Activa tion menu The control ports are also deleted when you del...

Страница 20: ...ises the alarm recall If an alarm recall is not recognised the PNG S repeats the alarm call a minimum of five times Then PNG OFF is dis played on the right display key You can initiate alarming signal...

Страница 21: ...ed alarm call and a pause The call and interval duration is s increased by one second after every alarm call Select a longer repeat alarm time for calls that break out into the public network The call...

Страница 22: ...me 90 s Alarm debounce time 1 s Prealarm time 15 s Transport Time 2 s Figure 7 2 Alarming signal time calculation The alarm debounce time is within the response time T0 Occurrence of monitored inciden...

Страница 23: ...ioning tone to be manually suppressed when the handset is in alarm mode The alarm positioning tone is suppressed for the du ration of the call once the key has been briefly pressed The alerting party...

Страница 24: ...prohibits the suspension or reactivation of automatic alarms when the handset is in monitoring mode Autom alarms OFF No All activated automatic alarms non movement man down time and pull cord alarms...

Страница 25: ...e Section 7 2 5 Control Ports This does not apply to the deliberate alarm or the technical fault warning The function requires the PNEZ control call The PNG LED displays the new monitoring mode Table...

Страница 26: ...ing signal is generated by pressing the handset s emergency key when an alarm is triggered The following parameters can be configured You can use the Alarm Signal Longpress setting to generate an alar...

Страница 27: ...to configure the individual Alarm destination and Alarm destina tion lp alarm destinations up to 32 digits for the deliberate alarm Table 7 9 Alarm destination settings for deliberate alarms Parameter...

Страница 28: ...h alarm type The alarm signal can be activated or deactivated for each alarm type You can select the sensitivity level of the escape alarm An individual alarm destination can be configured for each al...

Страница 29: ...leaning at an incorrect angle for a defined and configurable pe riod of time in other words the handset is in a non upright position Table 7 11 Parameter setting for man down alarm Parameter Setting...

Страница 30: ...defined and configurable period of time Table 7 13 Parameter setting for escape alarm Parameter Setting range Factory setting BGR 139 Activation On Off Off At least one autom alarm Response time 1 mi...

Страница 31: ...nitoring timers are restarted You can configure the following parameters Activation technical fault monitoring can be activated or deactivated Locate req time checks whether the handset is receiving r...

Страница 32: ...coustically signalled here The following signals start quietly and quickly rise in a crescendo to reach their configured max imum volume 7 2 4 1 Prealarm Configuration of acoustic prealarm signalling...

Страница 33: ...m and auto matic alarms Table 7 17 Parameter setting for the alarming signal 7 2 4 3 Technical Warning Configuration of acoustic warning signals for signalling local technical faults Table 7 18 Parame...

Страница 34: ...ciple The PNG S calls specific PNEZ control ports in order to signal PNG states or PNG requests Conversely the PNEZ control ports call the PNG S in order to initiate certain PNG control func tions on...

Страница 35: ...uest The PNG S would like to be includ ed in the monitoring process This phone number is called when the user selects the following menu item for instance Add Fea tures PNG Activation Number_2 and Num...

Страница 36: ...d Number_6 Number_5 and number_6 can be used to request the PNEZ to suspend or reactivate the configured automatic alarms Number_7 to Number_9 Reserved for later use PNG control function Number Start...

Страница 37: ...switched on The PNEZ can listen into the alarm situation and speak with the party signalling the alarm over the loudspeaker The call is disconnected from the PNEZ but can also be discon nected from t...

Страница 38: ...e numbers can consist of up to 32 digits The numbers are automatically derived and con figured from the PNEZ Basis Number_n PNEZ Basis n If required to do so you can overwrite the control ports and as...

Страница 39: ...000 You are now in the PNG Configuration menu 4 Select Adjust Sensor and confirm with OK The following text appears on the screen 5 Hold the handset still and in a vertical position and confirm with O...

Страница 40: ...ain menu 2 Select PNG Configuration 3 Enter the requested PNG Service PIN and confirm with OK the default PIN is 00000 You are now in the PNG Configuration menu 4 Select PNG Service PIN and confirm wi...

Страница 41: ...ing table contains the factory defaults Parameter Active General Settings Alarm Number Basis Blank PNEZ Basis Blank Alarm Call Count 15 Repeat Alarm Time 4 s Autom alarms OFF No Signal Off manual On S...

Страница 42: ...Alarm Number Basis Escape Alarm Activation Off Response time 30 s Prealarm time 15 s Alarm Signal On Sensitivity level Medium Alarm destination Alarm Number Basis Pull Cord Alarm Activation On Respons...

Страница 43: ...x professional Service Manual 43 PNG Configuration Factory Defaults Alarming signal Alarm Signal 04 Alarm signal volume Level 5 Technical Warning Alarm Signal 06 Alarm signal volume Level 3 Control Po...

Страница 44: ...on Activate the time alarm enable activation Set the response time for the time alarm 15 min The following are configured automatically based on the Alarm Number Basis PNEZ Basis Alarm destination 10...

Страница 45: ...Automatic 95000 Man Down Alarm Activation Input Off Response time 90 s Prealarm time 15 s Alarm Signal On Alarm destination Automatic 95000 Time Alarm Activation Input On Response time Input 15 Preala...

Страница 46: ...arm Acoustic On Alarm Signal 08 Alarm signal volume Level 3 Alarming signal Alarm Signal 04 Alarm signal volume Level 5 Technical Warning Alarm Signal 06 Alarm signal volume Level 3 Control Ports Star...

Страница 47: ...guration for Gigaset M2 plus and M2 Ex professional Service Manual 47 Sample Configurations Operation in HiPath Cordless Enterprise with PNEZ Sample change To change the alarm number for the pull cord...

Страница 48: ...e Alarm Number Basis in the example 95000 Delete the PNEZ Basis delete automatically generated number Deactivate the man down alarm disable activation Activate the time alarm enable activation Set the...

Страница 49: ...Automatic 95000 Man Down Alarm Activation Input Off Response time 90 s Prealarm time 15 s Alarm Signal On Alarm destination Automatic 95000 Time Alarm Activation Input On Response time Input 15 Preal...

Страница 50: ...larm Acoustic On Alarm Signal 08 Alarm signal volume Level 3 Alarming signal Alarm Signal 04 Alarm signal volume Level 5 Technical Warning Alarm Signal 06 Alarm signal volume Level 3 Control Ports Sta...

Страница 51: ...Example Alarm callback without PNEZ To be able to execute e g an alarm callback with silent monitoring the HiPath 3000 version must support the CLIP protocol in the setup message Configure e g the con...

Страница 52: ...the Alarm Number Basis in the example 95000 Delete the PNEZ Basis delete automatically generated number Deactivate the man down alarm disable activation Activate the time alarm enable activation Set...

Страница 53: ...tic 95000 Man Down Alarm Activation Input Off Response time 90 s Prealarm time 15 s Alarm Signal On Alarm destination Automatic 95000 Time Alarm Activation Input On Response time Input 15 Prealarm tim...

Страница 54: ...ustic On Out of range time 2 min Alarm Signal Prealarm Acoustic On Alarm Signal 08 Alarm signal volume Level 3 Alarming signal Alarm Signal 04 Alarm signal volume Level 5 Technical Warning Alarm Signa...

Страница 55: ...to suspend automatic alarms du ring charging Configure alarm via the emergency key Check Transport Time 2 s Configure automatic alarms Note At least one alarm must be switched on to guarantee configu...

Страница 56: ...Alarm signal volume OK Check the alarming signal Alarm destination selected OK Repeat Alarm Time OK Number of repeat alarms OK Activate monitoring Check automatic alarms all activated alarms Check the...

Страница 57: ...nal on off OK Alarm destination OK Check the escape alarm move device erratically simulate running Prealarm time OK Response time OK Signal on off OK Sensitivity level OK Alarm destination OK Check th...

Страница 58: ...times listed in this table are compulsory Alarm type Response time PNA PNA S Deliberate personal alarm for voice traffic otherwise Prealarm Automatic personal alarm including prealarm Man Down Alarm N...

Страница 59: ...g Line Identification Presentation CMI Cordless Multicell Integration DECT Digital Enhanced Cordless Telecommunications DPS DECT Positioning System HNA HiPath alarm signal system NOK Not OK PNA Person...

Страница 60: ...Conventions 5 D Data protection and data security 5 Debounce time 22 E Emergency 4 26 alarm destination 27 Alarm Signal 26 Escape Alarm 4 30 F Factory defaults 41 G General Settings 15 Repeat Alarm T...

Страница 61: ...ect Base 7 Sensor adjustment 39 Signal Off autom 24 Signal Off manual 23 Signal types 4 Symbols in the manual 5 T Technical warning 4 31 33 Time alarm 4 30 Time until prealarm 22 Transport Time 22 Typ...

Отзывы: