SHB_PNG07.fm
A31003-G2100-S100-2-7620, 03/2014
PNG Configuration for Gigaset M2
plus
and M2 Ex professional, Service Manual
25
PNG Configuration
Alarm Configuration
●
Autom. alarms OFF = By Control Call
The handset allows control calls from the PNEZ to suspend and re-activate the automatic
alarms activated during monitoring (see Section 7.2.5, “Control Ports”).
This does not apply to the deliberate alarm or the technical fault warning.
The function requires the PNEZ control call.
The PNG LED displays the new monitoring mode.
Table 7-7
Parameter setting for Autom. alarms OFF
7
This type of operation does not conform to BGR 139.
Parameter
Setting range
Factory setting
BGR 139
Autom. alarms OFF
No/
Off in charger/
By Control Call
No
No
(In compliance with
BGR 139 automatic
alarms are not sus-
pended during moni-
toring. The PNEZ
must remove them
from service.)