UTD2000M
User
Manual
Introduction
to
UTD2000CM
Series
Digital
Storage
Oscilloscope
UTD2000CM
Series
Digital
Storage
Oscilloscope
is
a
perfect
combination
of
user
‐
friendliness,
excellent
technical
indexes
and
multiple
functional
features.
A
unit
that
can
help
users
to
complete
their
measurement
work
faster.
This
Manual
contains
information
for
the
following
8
models
of
this
series
of
digital
storage
oscilloscope
Model
Bandwidth
Real
‐
time
sampling
rate
Maximum
memory
depth
UTD2042HM
40MHz
1GS/s
16Mpts
UTD2042CM
40MHz
1GS/s
32Mpts
UTD2062HM
60MHz
1GS/s
16Mpts
UTD2062CM
60MHz
1GS/s
32Mpts
UTD2102HM
100MHz
1GS/s
16Mpts
UTD2102CM
100MHz
1GS/s
32Mpts
UTD2202HM
200MHz
1GS/s
8Mpts
UTD2202CM
200MHz
1GS/s
16Mpts
UTD
2000CM
Series
Digital
Storage
Oscilloscopes
provide
users
with
simple
and
functionally
clear
front
panel
for
them
to
perform
all
basic
operations.
There
are
scale
and
position
knob
for
all
channels,
which
provides
intuitive
operation
that
conforms
to
the
usage
habits
of
conventional
instrument
users.
Users
can
operate
proficiently
without
the
need
to
spend
much
time
to
learn
and
get
familiar
with
its
operation.
To
speed
up
the
adjustment
for
the
ease
of
measurement,
the
instrument
will
display
suitable
waveform
and
range
once
the
users
press
AUTO
key
directly.
Aside
from
easy
to
use,
UTD
2000CM
Series
Digital
Storage
Oscilloscopes
has
the
high
performance
indexes
and
strong
functions
that
are
needed
to
complete
measuring
task
faster.
By
offering
real
‐
time
sampling
and
equivalent
sampling
at
the
rate
of
1GSa/s
and
50GSa/s
respectively,
faster
signals
can
be
observed
on
the
instrument.
The
strong
triggering
and
analytical
ability
has
made
it
easier
to
capture
and
analyze
waveform.
The
clear
LCD
and
mathematical
function
enable
users
to
observe
and
to
analyze
signal
issues
clearer
and
faster.
Following
features
may
help
you
understand
how
this
unit
can
meet
your
measurement
demand.
●
Double
analog
channel;
●
High
definition
color
LCD,
Resolution
800
×
480;
●
Waveform
capture
rate
up
to
150,000
wfms/s,
which
equals
to
75
times
of
that
of
the
competing
products;
●
Memory
depth
up
to
32
Mpts,
making
it
possible
for
the
instrument
to
maintain
the
highest
sampling
rate
8
Содержание UTD2000M
Страница 1: ...UTD2000CM User Manual ...
Страница 77: ...UTD2000M User Manual Fig 3 16 Pass Fail Detection Setting 1 Fig 3 17 Pass Fail Detection Setting 2 76 ...
Страница 92: ...UTD2000M User Manual This user manual may be revised without prior notice 91 ...
Страница 93: ...UTD2000M User Manual 92 ...
Страница 94: ...UTD2000M User Manual 93 ...