UTD2000M
User
Manual
System
Configuration
Auto
Calibration
System
Information
Clear
Information
Time
Settings
Factory
Settings
Contrast
Ratio
Run
auto
calibration;
Display
unit
mode,
version,
serial
number,
etc.;
Delete
reference
waveform
and
settings
saved;
Enter
into
time
and
date
settings,
see
Table
2
‐
28
Restore
to
factory
settings,
See
Appendix
E;
Adjust
contrast
ratio
of
the
screen;
Screen
Configuration
Language
Screen
Style
Menu
Display
Grid
Brightness
Return
Use
“MULTIPURPOSE”
knob
to
select
the
language
needed
and
press
the
same
knob
to
confirm;
Classic,
tradition
and
modern;
Set
the
waiting
time
before
a
menu
is
closed
automatically.
Optional
choices
are
5s,
10s,
20s
and
manual.
If
manual
is
selected,
the
unit
will
not
close
automatically.
It
needs
to
press
MENU
ON/OFF
to
close
or
open
it;
Use
“MULTIPURPOSE”
knob
to
adjust
the
grid
brightness
of
the
displaying
area;
Return
to
“auxiliary
function
menu”;
Pass
Detection
Open,
close
Detect
if
the
input
signal
is
within
the
preset
scope;
Waveform
Recording
See
Table
2
‐
27
Setup
the
waveform
recording;
Next
Page
Enter
into
Next
Page;
Table
2
‐
28
Auxiliary
Function
Menu
(2)
Menu
Setting
Description
Frequency
Meter
Open
&
Close
It
will
be
displayed
on
the
top
right
corner
of
the
screen,
see
remarks;
AUTO
Strategy
See
Table
2
‐
36
Conditional
settings
on
the
use
of
“Auto”;
Close
Menu
‐‐
Close
the
menu
display
shown
at
the
right
side
of
the
screen
(it
can
be
done
by
pressing
“menu
off/on”
key.)
Previous
Page
‐‐
Return
to
previous
page
Remarks:
Frequency
meter
is
the
counter
of
the
frequencies
of
trigger
events
that
are
occurred
in
the
trigger
channel.
Frequency
meter
is
only
valid
for
edge
or
pulse
width
triggering,
but
can
not
be
used
in
an
alternative
mode
of
trigger
source.
In
addition,
the
trigger
related
frequency
meter
is
invalid
for
video
triggering.
Table
2
‐
29
Pass
Detection
(1)
Menu
Setting
Description
Allow
Detection
Close
Open
Open
“Pass/Fail”
Detection.
Output
Pass
Fail
Confirm
the
buzzer
and
the
output
condition
of
“Pass/Fail”
interface
located
behind
the
oscilloscope.
Signal
Source
CH1
CH2
Choose
the
signal
source
under
test.
Display
Information
Open
Close
Choose
whether
or
not
to
display
statistical
information
on
the
screen
Next
Page
——
Enter
into
next
page
Table
2
‐
30
Pass
Detection
(2)
Menu
Setting
Description
Operation
Stop
Stop
“Pass/Fail”
detection.
57