UTD2000M
User
Manual
Fig.
2
‐
18
Screen
Display
for
Expanded
Window
Under
window
expansion
mode,
the
screen
is
separated
into
two
displaying
area,
which
is
shown
above.
Original
waveform
is
being
displayed
in
the
upper
part
which
allows
horizontal
shifting
by
turning
“POSITION”
knob
or
by
turning
horizontal
“SEC/DIV”
knob
to
enlarge
or
reduce
the
selected
area.
The
lower
part
shows
horizontal
expanded
waveform.
What
is
worth
noting
is
that
expanded
time
base
has
improved
the
resolution
if
compared
with
main
time
base
(as
shown
above).
Since
the
waveform
being
displayed
in
the
lower
part
corresponds
to
the
selected
area
shown
in
upper
part,
turning
horizontal
“SEC/DIV”
knob
to
reduce
selected
area
can
help
improve
expanded
time
base,
as
it
improves
the
horizontal
amplification
factor
for
such
waveform.
Notes:
Maximum
expanded
time
base
is
50ns/div.
2.4
Trigger
System
Settings
The
triggering
act
determines
when
the
digital
storage
oscilloscope
begins
to
collect
data
and
displays
waveform.
Once
the
trigger
has
been
set
correctly,
it
can
transform
unstable
display
into
meaningful
waveforms.
When
the
digital
storage
oscilloscope
begins
to
collect
data,
it
first
collects
enough
data
to
draw
a
waveform
at
the
left
side
of
the
trigger
point.
While
the
instrument
is
waiting
for
the
occurrence
of
a
triggering
condition,
it
is
also
collecting
data
consecutively.
When
a
trigger
condition
is
detected,
the
instrument
will
collect
sufficient
data
consecutively
so
as
to
draw
a
waveform
at
the
right
side
of
the
trigger
point.
The
trigger
control
area
shown
on
operation
panel
of
UTD2000CM
‐
EDU
series
oscilloscope
includes
“LEVEL”
knob
(for
trigger
level),
MENU
key,
FORCE
key
(for
force
trigger)
and
SINGLE
key
(for
single
trigger).
“LEVEL”
Knob
(For
Trigger
Level)
Use
“LEVEL”
control
in
“Trigger
Section”
to
adjust
trigger
level.
When
trigger
level
is
being
adjusted,
there
will
be
a
horizontal
line
appearing
on
the
screen
temporarily
to
indicate
electrical
level.
When
this
line
disappears,
trigger
level
will
be
marked
as
a
small
arrow.
Press
“LEVEL”
knob
to
set
trigger
level
as
equal
to
50%
of
the
amplitude
of
original
waveform
triggered.
Force
Trigger
FORCE
Press
FORCE
key
(for
force
trigger)
to
force
trigger
an
immediate
trigger
event.
This
function
can
be
used
in
following
aspects:
When
using
“Normal”
trigger
mode,
if
no
waveform
is
shown
on
the
screen,
press
FORCE
(force
trigger)
key
33
Содержание UTD2000M
Страница 1: ...UTD2000CM User Manual ...
Страница 77: ...UTD2000M User Manual Fig 3 16 Pass Fail Detection Setting 1 Fig 3 17 Pass Fail Detection Setting 2 76 ...
Страница 92: ...UTD2000M User Manual This user manual may be revised without prior notice 91 ...
Страница 93: ...UTD2000M User Manual 92 ...
Страница 94: ...UTD2000M User Manual 93 ...