User’s Manual MSO/UPO2000 Seri es
134 / 137
Instruments.uni-trend.com
In XY mode, this function cannot
be use
!
It will be prompt when open MATH, REF, LA, DECODE function in XY
mode.
Start to update
?
It will be prompt when select the update file to upgrade.
The channel is not open
!
It will be prompt if the selected channel is not opened in cursor
measurement, Pass/Fail template, channel waveform storage,
arbitrary waveform storage function.
Turn on allow to test
!
It will be prompt when allow to test function is disabled.
Waveform reference channel is
not open, there is no valid data
!
It will be prompt if REF is not loading adjusting horizontal or vertical
when waveform reference is select REF in Pass/Fail test.
It’s not allow to test in XY and the
main window mode
!
It will be prompt when Pass/Fail test and XY mode is enabled.
Turn off scanning
!
It will be prompt if press other key when it in scanning.
There is no opened channel,
please turn on channel to
record
!
It will be prompt if all analog channel is turned off when in recording
waveform.
In Multi-Scopes, LA is forbidden!
It will be prompt when turn on Multi-Scopes function and then open
LA.
In FFT split screen mode, this
function is invalid
!
It will be prompt when using Pass/Fail test, bode diagram, reload
waveform, LA function in FFT split screen, waterfall curve mode.
In FFT split screen mode,
Pass/Fail test is forbidden
!
It will be prompt when turn on Pass/Fail test function and then open
FFT split screen.
The file list is empty
!
It will be prompt when if the filename is empty when reload
reference waveform, the setting file and bode diagram.
Auto-calibration is canceled
!
It will be prompt if press MENU key to cancel auto-calibration when
in auto-calibration.
Restored to factory setting,
internet parameter is not
change
!
It will be prompt when SCPI is connect the internet to send factory
setting command.
Shunt down, please wait...
It will be prompt when the oscilloscope is shutting down.
Turn off quick record and set
record interval
!
It will be prompt when set the time interval in quick record.
No correct license is detected.
Confirm the purchase and try
again
!
It will be prompt if there is no correct license when insert USB to
activate the optional.
Activation is successful
!
It will be prompt when activation license is selected in USB.
This function is not activated,
please purchase activation
code
!
It will be prompt when select the optional after the trail is ended.
The function is in trail. If need to
use it in the long run, please
purchase activation code
!
It will be prompt if select the optional when it in trail.