SK00-4802-DI-002-04
No.16.10.20
viii
Cooling Water Piping <Removal>
If the joints for cooling water are removed immediately after the pump
operation stops, the cooling water remaining in the pump may come to a
boil and spout. Supply the cooling water until the pump temperature
becomes low.
The pump keeps its temperature extremely high while the pump is running
or for a while after it stops. If someone's body comes into contact with it,
the person may get burned. Supply the cooling water until the pump
temperature becomes low.
With a visually observable flowmeter (HWFM: such as a flow sight) of the
cooling water supply source for devices, check that no water flows.
Intake and exhaust piping <Removal>
Remove
according to the installation manual of the device.
The pumping lines stay at extremely high temperatures for a while even
after the pump stops. Make sure that the pump temperature is low before
removing it.
Fully
seal the intake and exhaust ports using shutoff flanges etc.
Transportation
The pump mass is as follows.
ULK-04A : 7.5kg
ULK-06A : 13.5kg
ULK-10A : 47kg
ULK-14A : 56kg
For transfer, loading equal to or higher than the safety standards is
necessary depending on the model and you may damage your back.
Transport it by hanging with cargo handling equipment (such as a mobile
crane), or put and fix it on a pallet and transport it on a pallet track.
WARNING
WARNING