RF Power Supply and Matching Box
4. Functions
44
* Loading a preset from PRESET No. 2 is given as an example in the timing chart.
4-2-5. Caution when using the external control terminals (AMC.EXT/PRESET)
If connecting an inductive load (relay or coil) to the output of the external control terminal, insert a diode
or use a relay with a surge absorbing element so that counter-electromotive force is not generated.
Figure 4-10 Timing chart during external recall operation (loading) (AMC-9L/AMC-9LT)
Figure 4-11. Overvoltage protection circuit for transistor/output section
AUTO/MANUAL switch
(AMC.EXT[1-9])
Open
Close
Open
Close
SELECT1
(SELECT[3-11])
SELECT2
(SELECT[4-12])
SELECT3
(SELECT[5-13])
SELECT4
(SELECT[6-14])
RECALL
(SELECT[2-10])
Close
Open
100 ms or more
50 ms or more
BUSY
(AMC.EXT[2-10])
Variable capacitors operating
Counter EMF
prevention
diode
+24V